Skip to main content
Siemens 3VA1132-3EF32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3EF32-0JC0 SENTRON MCCB, 32 A, 75.6 kA at 24

MPN3VA1132-3EF32-0JC0

Siemens SENTRON 3VA1132-3EF32-0JC0, 3-pole molded case circuit breaker, 32 A (40 °C), 75.6 kA at 240 V, line protection, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-3EF32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11323EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1132-3EF32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.6 W

Protection & Trip Unit

3VA1132-3EF32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1132-3EF32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-3EF32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1132-3EF32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-3EF32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1132-3EF32-0JC0 is a SENTRON 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 32 A continuously at 40 °C and interrupting up to 75.6 kA at 240 V. That interrupting rating drops to 52.5 kA at 415 V and 32 kA at 440 V, so the breaker's fault-clearing capability scales with system voltage — a key selectivity consideration when coordinating downstream devices. Thermal derating stays flat at 32 A from 40 °C through 50 °C, then steps down to 31 A at 55 °C and 60 °C, and 30 A at 65 °C and 70 °C — useful if the panel runs warm near other heat sources.

Physical Fit & Integration

The breaker measures 70 mm deep by 76.2 mm wide by 130 mm high — a standard panel-mount footprint for the SENTRON 3VA frame. It accepts screw-type or busbar connections and integrates into DIN-rail or backplate assemblies. Maximum power dissipation is 10.6 W, so ventilation in a sealed enclosure should account for that heat load.

Frequently asked questions

How do I get current pricing and availability for 3VA1132-3EF32-0JC0?

Submit an RFQ through this listing. The part is sourced to order; pricing and stock levels are confirmed at quote time.

What is the closest functional second-source to 3VA1132-3EF32-0JC0?

The 3VA1110-5EF32-0AM0 is a lower-current sibling in the same SENTRON 3VA family — same 3-pole form factor and similar interrupting ratings, but rated at a lower continuous current. Panel rewiring is not required for the same frame size, but the trip unit calibration differs.

What are the key interrupting ratings for 3VA1132-3EF32-0JC0?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V.

MPN
3VA1132-3EF32-0JC0