Siemens 3VA1132-3EF36-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3EF36-0DH0 Circuit Breaker, 32 A, 25 kA @ 41

MPN3VA1132-3EF36-0DH0

Siemens 3VA1 series, IEC frame 160, breaking capacity class N, 3-pole, 25 kA @ 415 V, TM240 thermal-magnetic trip, In=32 A, undervoltage release 208-230 V AC, 2 auxiliary switches + trip alarm, clamp terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1132-3EF36-0DH0 is a 3-pole IEC frame 160 molded-case circuit breaker with a 25 kA interrupting capacity at 415 V (class N). That rating puts it on the line-side of a 160 A panelboard or a motor control center feeder — it clears a bolted fault up to 25 kA without the arc flashing upstream. The TM240 thermal-magnetic trip unit is set for a 32 A continuous rating (In), with the overload (Ir) adjustable from 22 to 32 A via a dial on the face. That adjustability means one SKU covers a range of downstream loads; you dial Ir to match the cable or motor FLA, not the other way around.

Clamp terminals accept copper or aluminum conductors without lug kits — speeds up panel wiring. The built-in undervoltage release (UVR) operates on 208-230 V AC, 50/60 Hz; it drops the breaker open when control voltage falls below about 85% of rated, which is standard for emergency-stop or power-loss sequences in IEC panels. Two auxiliary switches (HQ) plus a separate trip-alarm switch (HQ) give you status feedback for a PLC or a remote annunciator — one NO/NC pair for the breaker position, another for the trip event.

Frequently asked questions

What is the breaking capacity of this breaker?

It is rated 25 kA at 415 V AC, breaking capacity class N per IEC 60947-2. That is the standard interrupting rating for general-purpose distribution in most 400 V industrial panels.

What does the TM240 trip unit mean?

TM240 is a thermal-magnetic trip block with a fixed magnetic pickup (short-circuit protection Ii) adjustable from 5 to 10 times In (160 to 320 A for the 32 A rating). The thermal overload (Ir) is adjustable from 22 to 32 A via a dial. It is a line-protection curve, not a motor-protection curve — use it for cable and busbar protection, not for direct motor overload duty.

Where can I buy 3VA1132-3EF36-0DH0?

This part is sourced and quoted to order through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time. No stock count or price is published here.