Siemens 3VA1132-3GD42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3GD42-0AA0-ZD00 Circuit Breaker, 32A, 25kA @

MPN3VA1132-3GD42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 4-pole MCCB, 32 A fixed thermal-magnetic, 25 kA Icu @ 415 V, breaking capacity class N, line protection TM210, N-conductor protection 100%, nut keeper kit, DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1132-3GD42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker (MCCB) from the 3VA1 series, rated for line protection with a fixed 32 A thermal-magnetic trip unit (TM210). Breaking capacity class N delivers 25 kA Icu at 415 V — enough for most industrial distribution panels downstream of a larger main breaker. The N-conductor protection is set at 100%, and the unit includes a nut keeper kit; it was configured for a DC Power OEM in China.

What the ratings mean for your panel

The 25 kA Icu @ 415 V (breaking capacity class N per IEC 60947-2) tells you this breaker can safely interrupt a fault up to that level without welding its contacts or rupturing the enclosure. In a typical 400 V industrial supply with a transformer rating under 1 MVA, that's enough headroom for downstream feeder protection — you won't need a current-limiting upstream breaker just to protect this one. The fixed 32 A overload setting (Ir = 32 A) and fixed short-circuit pickup (Ii = 10 x In = 320 A) mean the trip curve is non-adjustable. That simplifies ordering but locks the coordination: verify the 320 A magnetic pickup doesn't overlap with the inrush of the load (motors, transformers) you're protecting. The TM210 designation indicates a thermal-magnetic trip with a 10x In magnetic threshold — standard for general-purpose feeder and branch protection.

Frequently asked questions

Where can I buy 3VA1132-3GD42-0AA0-ZD00 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing.

What is the breaking capacity of this breaker?

It has a rated ultimate breaking capacity (Icu) of 25 kA at 415 V, breaking capacity class N per IEC 60947-2.

What does the TM210 designation mean?

TM210 indicates a thermal-magnetic trip unit with a fixed overload rating (Ir = 32 A) and a fixed short-circuit pickup set at 10 times In (Ii = 320 A).

MPN
3VA1132-3GD42-0AA0-ZD00