Skip to main content
Siemens 3VA1132-4EF32-0AB0 — Molded Case Circuit Breakers (MCCB)

3VA1132-4EF32-0AB0 SENTRON MCCB, 32 A, 3-pole, 121 kA at 240

MPN3VA1132-4EF32-0AB0

Siemens SENTRON 3VA1132-4EF32-0AB0, molded case circuit breaker, 3-pole, 32 A rated at 40 °C, 121 kA breaking capacity at 240 V AC, TM240 overcurrent release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-4EF32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11324EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1132-4EF32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.6 W
3VA1132-4EF32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1132-4EF32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-4EF32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1132-4EF32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-4EF32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a continuous current of 32 A up to 40 °C, with thermal derating that holds 32 A through 50 °C and steps down to 30 A at 70 °C — a flat thermal curve that simplifies panel sizing in warm enclosures. Breaking capacity is the headline: 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. Those numbers mean this breaker can sit upstream of a high-fault panel without cascading — the 121 kA at 240 V covers most North American 277/480 V distribution scenarios where the line-to-neutral fault is the worst case.

Footprint: 76.2 mm wide (3 in), 130 mm tall (5.12 in), 70 mm deep (2.76 in). The 76.2 mm width is a standard 3-pole MCCB module — it occupies three 25.4 mm (1 in) mounting slots on a DIN rail or panel-mount adapter.

Overcurrent release and auxiliary contacts

The TM240 overcurrent release is a thermal-magnetic type — thermal element for overload protection, magnetic trip for short-circuit.

Frequently asked questions

Where can I buy 3VA1132-4EF32-0AB0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1132-4EF32-0AB0 at 240 V?

121 kA at 240 V AC, which covers most North American 277/480 V distribution fault scenarios.

Does 3VA1132-4EF32-0AB0 include auxiliary contacts?

Yes, it ships with two high-performance auxiliary switches pre-installed.

MPN
3VA1132-4EF32-0AB0