Siemens 3VA1132-4EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-4EF32-0DH0 Circuit Breaker, 36kA @ 415V, 32A

MPN3VA1132-4EF32-0DH0

Siemens 3VA1 IEC frame 160, breaking capacity class S, 3-pole circuit breaker, Icu=36kA @ 415V, TM240 thermal-magnetic trip unit, In=32A, Ir=22-32A, Ii=5-10xIn, with undervoltage release (UVR) 208-230V AC, 2 HQ auxiliary switches, 1 HQ trip alarm switch, nut keeper kit.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What the ratings mean for the panel

The 3VA1132-4EF32-0DH0 is a Siemens 3VA1 IEC frame 160 molded case circuit breaker with a breaking capacity class S rating of Icu=36kA at 415V AC. That 36kA interrupting rating means it can safely clear a fault current up to that level without rupturing — critical for main or feeder breakers in high-fault panels where the available short-circuit current exceeds 25kA. The 3-pole construction suits three-phase line protection. The TM240 thermal-magnetic trip unit provides overload protection adjustable from Ir=22A to 32A (In=32A fixed rating), and short-circuit protection set at Ii=5 to 10 times In. For a 32A breaker, that means the magnetic instantaneous trip can be dialed between 160A and 320A — useful for coordinating with downstream branch breakers or motor starters that have higher inrush. This variant ships with an undervoltage release (UVR) rated 208-230V AC 50/60Hz, two HQ auxiliary switches, and one HQ trip alarm switch. The UVR automatically trips the breaker when control voltage drops below about 70% of rated — standard for emergency-stop circuits or undervoltage protection on machine tools. The HQ auxiliary switches provide a positive-break contact for status feedback to a PLC or safety relay.

Sourcing and lifecycle

For BOM freeze or project planning: this part is specified into the Siemens 3VA1 platform, which is the current-generation IEC molded case breaker family replacing the older 3VL series. The 3VA1 line shares the same mounting footprint and accessory ecosystem, so panel layouts already using 3VL breakers can generally retrofit with a 3VA1 without re-drilling the backplate.

Deployment context

The 3VA1 frame 160 mounts on a standard DIN rail or can be screw-fixed to a backplate. In a typical 600mm-wide enclosure, you can fit up to four 3-pole units side by side with the required side-to-side clearance for heat dissipation. The nut keeper kit (included) simplifies panel wiring by holding the terminal nuts captive during conductor installation — a small time-saver when you're landing dozens of feeders. The UVR coil draws continuous power when the breaker is closed; factor that into your 24V DC control transformer sizing if the UVR is fed from the same supply as PLCs or relays. The HQ auxiliary switches are rated for 6A 250V AC, adequate for pilot-duty signaling to a 24V DC input card.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA1132-4EF32-0DH0 has a breaking capacity class S rating of Icu=36kA at 415V AC, suitable for high-fault installations.

What accessories are included with this order code?

This variant includes an undervoltage release (UVR) rated 208-230V AC 50/60Hz, two HQ auxiliary switches, one HQ trip alarm switch, and a nut keeper kit.

How do I get pricing and availability for 3VA1132-4EF32-0DH0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent distribution network.