Skip to main content
Siemens 3VA1132-4EF32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-4EF32-0HC0 SENTRON MCCB, 32 A, 121 kA at 240

MPN3VA1132-4EF32-0HC0

Siemens SENTRON 3VA1132-4EF32-0HC0, 3-pole molded case circuit breaker, line protection, 32 A rated continuous current, TM240 overcurrent release, 121 kA interrupting at 240 V, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-4EF32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1132-4EF32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1132-4EF32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1132-4EF32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-4EF32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1132-4EF32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-4EF32-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The 3VA1132-4EF32-0HC0: The 32 A continuous rating holds flat from 40 °C to 50 °C, then derates to 30.72 A at 55 °C, 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C. The 121 kA at 240 V means it safely interrupts fault currents up to that level without upstream cascading; at 690 V the same breaker handles 11.9 kA, so verify the available fault current at the point of installation.

Auxiliary and release configuration

The integrated auxiliary trip is order code 3VA9688-0BL30.

Frequently asked questions

What is the depth of 3VA1132-4EF32-0HC0?

The depth is 70 mm.

What is the width of 3VA1132-4EF32-0HC0?

The width is 76.2 mm.

Does 3VA1132-4EF32-0HC0 include a shunt trip?

Yes, it includes a shunt trip (STL) auxiliary release and two high-quality auxiliary switches.

MPN
3VA1132-4EF32-0HC0