Skip to main content
Siemens 3VA1132-5ED16-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-5ED16-0AA0 SENTRON MCCB, 1-Pole, 32 A, 121 k

MPN3VA1132-5ED16-0AA0
Active

Siemens SENTRON 3VA1132-5ED16-0AA0, molded case circuit breaker, 1-pole, TM210 trip unit, 32 A rated at 40 °C, 121 kA interrupting at 240 V AC, 70 mm depth, 25.4 mm width, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-5ED16-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1132-5ED16-0AA0 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classM
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V9 kA
Power loss, max.3.53 W

Protection & Trip Unit

3VA1132-5ED16-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1132-5ED16-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-5ED16-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1132-5ED16-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-5ED16-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

What this MCCB is and what it does

The Siemens 3VA1132-5ED16-0AA0 is a 1-pole SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a TM210 thermal-magnetic trip unit, rated 32 A continuously at 40 °C ambient, with the same rating holding through 50 °C before a slight derate to 30 A at 70 °C. The interrupting capacity is 121 kA at 240 V AC — that means it can safely clear a fault up to that level without welding contacts or rupturing the case, which is the figure that governs whether it holds on a high-fault-capacity service entrance or a transformer secondary.

Panel fit and integration

At 25.4 mm wide and 70 mm deep, this single-pole breaker occupies one standard 1-inch module on a DIN rail. The IP40 front protection means it's fine inside a closed panel but not for washdown or outdoor exposure. No auxiliary contacts, no undervoltage release, no communication module — this is a bare line-protection device; any add-ons (shunt trip, alarm switch) must be ordered separately and snap onto the left side of the breaker.

Frequently asked questions

What is the interrupting rating of this MCCB?

121 kA at 240 V AC, and 9 kA at 415 V AC. The 240 V figure is the one that matters for most North American service-entrance applications.

What is the width of 3VA1132-5ED16-0AA0?

25.4 mm (1 inch), which is one standard DIN-rail module.

What is the depth of this breaker?

70 mm (2.76 inches).

Where can I buy 3VA1132-5ED16-0AA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does this breaker include an undervoltage release or shunt trip?

No. It is a bare line-protection device with no undervoltage release, no auxiliary contacts, and no communication function. Add-on accessories must be ordered separately.

MPN
3VA1132-5ED16-0AA0