Skip to main content
Siemens 3VA1132-5ED26-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1132-5ED26-0AA0 MCCB, 2-Pole, 32 A, 187 k

MPN3VA1132-5ED26-0AA0
Active

Siemens SENTRON 3VA1132-5ED26-0AA0, 2-pole molded case circuit breaker (MCCB), 32 A rated at 40 °C, 187 kA interrupting at 240 V, TM210 release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-5ED26-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1132-5ED26-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Power loss, max.7.06 W
3VA1132-5ED26-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1132-5ED26-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-5ED26-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1132-5ED26-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-5ED26-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The 3VA1132-5ED26-0AA0 is a 2-pole SENTRON molded case circuit breaker rated 32 A continuous at 40 °C, with a TM210 thermal-magnetic release tuned for line protection — meaning it handles overload and short-circuit in one device, no external relay needed. Interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V AC, so it clears high-fault conditions without cascading upstream on a 415 V panel feed.

Panel fit and thermal derating

Footprint is 50.8 mm wide (2 in), 130 mm tall, 70 mm deep — two-pole width on a DIN-rail or panel-mount assembly, so it occupies one standard MCCB slot. Current rating holds flat at 32 A from 40 °C through 50 °C, then steps down to 31 A at 55–60 °C, and 30 A at 65–70 °C. No derating needed for most ventilated enclosures; at 70 °C ambient you lose 2 A.

Frequently asked questions

Will 3VA1132-5ED26-0AA0 drop into a panel specified for 3VA1110-5ED36-0AA0?

Both are 2-pole SENTRON MCCBs with the same 50.8 mm width and 70 mm depth, so the mechanical fit is the same — but the 3VA1110-5ED36-0AA0 carries a different current rating and interrupting capacity; verify the load side before swapping.

MPN
3VA1132-5ED26-0AA0