Skip to main content
Siemens 3VA1132-5EF36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-5EF36-0BC0 SENTRON MCCB, 32 A, 3-pole

MPN3VA1132-5EF36-0BC0

Siemens SENTRON 3VA1132-5EF36-0BC0, molded case circuit breaker, 3-pole, 32 A rated continuous current (Iu), TM240 thermal-magnetic release, 187 kA breaking capacity at 240 V, undervoltage release, 2 HQ auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-5EF36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1132-5EF36-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA

Protection & Trip Unit

3VA1132-5EF36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1132-5EF36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-5EF36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1132-5EF36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-5EF36-0BC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Line protection MCCB, 32 A frame

The Siemens SENTRON 3VA1132-5EF36-0BC0 is a 3-pole molded case circuit breaker rated for 32 A continuous current (Iu) with a TM240 thermal-magnetic overcurrent release. Its 187 kA breaking capacity at 240 V AC means it can safely interrupt fault currents up to that level without upstream cascading — critical for high-fault installations like transformer secondaries or large motor control centers. At 415 V the rating holds at 121 kA, and at 690 V it still clears 17 kA, so the part handles standard industrial supply voltages across the board. The TM240 release is a fixed thermal-magnetic design — no interchangeable trip units — so the 32 A rating is locked at order. If your BOM calls for adjustable or electronic trip curves, this isn't the variant; but for straightforward line protection where the load current is stable, it's a clean, single-part-number solution. The 800 V rated insulation voltage (Ui) gives headroom for 690 V systems without derating the insulation path.

Auxiliaries and releases

This unit ships with an undervoltage release (UVR) integrated — when control voltage drops below the dropout threshold, the breaker trips, which is standard for safety circuits that need to disconnect on power loss. The auxiliary contact block is a 2-switch HQ version (high-rupturing-capacity auxiliary contacts), and the integrated auxiliary trip is order code 3VA9608-0BB11. No communication module, no ground-fault monitoring, no voltage trigger — it's a pure thermal-magnetic line protection breaker with undervoltage supervision.

Thermal derating and panel fit

The breaker holds full 32 A from 40 °C up to 50 °C ambient. At 55 °C it derates to 30.72 A, at 65 °C to 29.44 A, and at 70 °C (the maximum operating ambient) to 28.8 A. If your panel runs hot — say a crowded enclosure near a furnace line — check the 55 °C and 60 °C columns before committing the BOM. The front face carries IP40 protection, so it's fine for general-purpose indoor panels but not for washdown or outdoor exposure without an enclosure. Dimensions: 76.2 mm wide (roughly 3 inches — standard 3-pole MCCB footprint), 130 mm tall, 70 mm deep. The width is the critical fit dimension for DIN-rail or panel-mount spacing; at 76.2 mm it occupies the same slot as most 3-pole SENTRON frames, so swapping in a panel built for the 3VA1110 or 3VA1112 series should work without drilling new holes or moving the busbars.

Frequently asked questions

Where can I buy 3VA1132-5EF36-0BC0 and what is the lead time?

We source this part to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ and we will return firm lead time and price.

What is the breaking capacity of this MCCB at different voltages?

At 240 V it clears 187 kA, at 415 V it clears 121 kA, at 440 V it clears 75.6 kA, and at 690 V it clears 17 kA. These are the maximum fault currents the breaker can safely interrupt at each voltage level.

Will 3VA1132-5EF36-0BC0 fit in a panel built for 3VA1110-5EE32-0DC0?

The physical dimensions are nearly identical — both are 3-pole SENTRON frames at 76.2 mm wide, 130 mm tall, and 70 mm deep. The busbar spacing and DIN-rail clip pattern are the same across the 3VA family, so mechanical fit should be fine without rewiring or re-drilling.

What compliance documentation does Siemens provide for this MCCB?

As a current-production SENTRON series part, Siemens provides CE declaration of conformity, IEC/EN 60947-2 test reports, and regional UL/CSA certifications depending on the variant. RoHS and REACH compliance declarations are standard. Request specific documentation at quote time.

MPN