Siemens 3VA1132-5EF36-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-5EF36-0HH0 SENTRON MCCB, 3-Pole, 32 A, 187 k

MPN3VA1132-5EF36-0HH0

Siemens SENTRON 3VA1 molded case circuit breaker, 3-pole, 32 A rated current, 187 kA breaking capacity at 240 VAC, line protection design, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-5EF36-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11325EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1132-5EF36-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W

Protection & Trip Unit

3VA1132-5EF36-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1132-5EF36-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-5EF36-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1132-5EF36-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-5EF36-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1132-5EF36-0HH0 — 32 A SENTRON MCCB with 187 kA Interrupting Capacity

The Siemens 3VA1132-5EF36-0HH0 is a 3-pole SENTRON molded case circuit breaker rated for 32 A continuous current at 40 °C ambient, with a breaking capacity of 187 kA at 240 VAC — that's the short-circuit current it can safely interrupt without welding contacts or rupturing the case, which matters when you're coordinating downstream feeders in a high-fault panel. Breaking capacity drops as voltage rises: 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V. For a 400 V distribution board, the 121 kA figure is the one to use in your selectivity study. Thermal rating holds at 32 A from 40 °C through 50 °C, then derates to 31 A at 55–60 °C and 30 A at 65–70 °C. If the panel ambient runs hot, the 30 A ceiling at 70 °C is your real limit. Rated insulation voltage is 800 V, so the breaker is suitable for 690 V line-to-line systems with margin. The design is line protection (not motor protection), meaning it's intended for feeder and distribution duty, not overload protection of a motor circuit.

Built-in Accessories and Panel Fit

This variant ships with a shunt trip release (STL) for remote tripping, plus two auxiliary switches and one trip alarm switch (HQ configuration). That's enough status feedback for a PLC input card without adding external relays. Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage limit governs shipping and warehouse conditions, not running duty. Maximum power loss is 10.6 W — relevant for thermal budgeting inside a sealed enclosure. No undervoltage release, no ground-fault monitoring, no communication function on this order code.

Frequently asked questions

What accessories are included on this order code?

It includes a shunt trip release (STL) for remote tripping, two auxiliary switches, and one trip alarm switch (HQ). No undervoltage release or ground-fault monitoring.

MPN
3VA1132-5EF36-0HH0