Siemens 3VA1132-5GD42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-5GD42-0AA0 SENTRON MCCB, 32A, 4-Pole, 187kA

MPN3VA1132-5GD42-0AA0
Active

Siemens SENTRON 3VA1 series, molded case circuit breaker, 3VA1132-5GD42-0AA0, 4-pole, 32 A rated current, TM210 release, line protection, 187 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-5GD42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1132-5GD42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W

Protection & Trip Unit

3VA1132-5GD42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1132-5GD42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-5GD42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1132-5GD42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-5GD42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

32 A MCCB with 187 kA interrupt rating — the line-protection variant

The Siemens SENTRON 3VA1132-5GD42-0AA0 is a 4-pole molded case circuit breaker (MCCB) carrying a permanent rated current Iu of 32 A at 40 °C, with the TM210 thermal-magnetic release tuned for line protection rather than motor or generator duty. The TM210 designation means the thermal pickup is fixed at 1.0 × In and the magnetic short-circuit trip is set at 10 × In — a standard distribution profile that avoids nuisance tripping on transformer inrush or capacitor banks. Breaking capacity hits 187 kA at 240 V AC and still delivers 121 kA at 415 V and 75.6 kA at 440 V, tapering to 17 kA at 500 V and 690 V. Those figures place it comfortably above typical utility fault levels for North American 480Y/277 V and European 400 V panels — the SCCR headroom means it can be installed without cascading an upstream current-limiting fuse for most industrial service entrances. Panel footprint is 130 mm high × 101.6 mm wide × 70 mm deep, with IP40 protection on the front face. The 100 % N-conductor protection design means the neutral pole is fully rated — no derating needed when feeding single-phase loads from a 4-pole breaker in a three-phase-plus-neutral system.

Thermal derating and operating envelope

Rated current holds at 32 A from 40 °C through 50 °C ambient, then gently tapers to 31 A at 55–60 °C and 30 A at 65–70 °C. The maximum operating temperature is 70 °C, with a minimum of −25 °C; storage range extends from −40 °C to 80 °C. Power loss at rated load is 10.6 W maximum — negligible for panel thermal budgeting but worth checking if the breaker is tightly ganged in a multi-unit enclosure. Rated insulation voltage Ui is 800 V, and the maximum rated operational voltage Ue in DC circuits is 600 V. The IP40 front protection means the breaker face is sealed against tools and small solids but not against water ingress — appropriate for dry indoor panelboards, not washdown zones.

Lifecycle and sourcing posture

The breaker accepts an optional motor drive, which is relevant for remote-tripping or generator-paralleling schemes. No communication function is built in — this is a standalone thermal-magnetic MCCB, not a communicating power breaker. Ground-fault monitoring is not included; a separate GF module or upstream RCD would be needed for personnel protection.

Integration and panel fit

The 101.6 mm width matches the standard 4-inch MCCB pole spacing for North American panelboards — a direct swap into existing SENTRON 3VA1 or competitive 4-pole breaker slots without bus-bar rework. Depth of 70 mm keeps the breaker inside typical 6-inch deep enclosures without door interference. Reference code per IEC 81346-2 is Q (switching device). The front face carries IP40 protection, which is adequate for most IEC 61439 switchboard assemblies where the breaker is behind a door or cover.

Frequently asked questions

What is the breaking capacity of 3VA1132-5GD42-0AA0 at 240 V?

187 kA at 240 V AC, dropping to 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V. The 187 kA figure covers most North American utility fault levels without requiring upstream current-limiting fuses.

How do I get current pricing and availability for 3VA1132-5GD42-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What compliance documentation does Siemens provide for this MCCB?

The breaker carries the SENTRON brand with IEC 60947-2 design compliance. Specific RoHS, REACH, UL, and IEC declarations are part of the standard Siemens documentation package available on request.

MPN
3VA1132-5GD42-0AA0