Skip to main content
Siemens 3VA1132-5GF42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-5GF42-0AA0 SENTRON MCCB, 32A, 4-Pole, 187kA

MPN3VA1132-5GF42-0AA0
Active

Siemens SENTRON 3VA1132-5GF42-0AA0, molded case circuit breaker, 4-pole, 32 A, TM240 thermal-magnetic release, 187 kA breaking capacity at 240 VAC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-5GF42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1132-5GF42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W
3VA1132-5GF42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1132-5GF42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-5GF42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1132-5GF42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-5GF42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Thermal derating — the real-world current you can actually run

At 55 °C it derates to 31 A, holds there through 60 °C, then drops to 30 A at 65 °C and 70 °C. That's a clean, predictable curve — no surprise trip at the top of a hot summer day in a non-conditioned electrical room.

Dimensions are 101.6 mm wide (4 in), 130 mm tall (5.12 in), and 70 mm deep (2.76 in).

For a BOM freeze or a line-down replacement, the key fit parameters are the 32 A TM240 release, the 4-pole configuration, and the 187 kA interrupting rating at 240 V — confirm those match your existing coordination study and the page is good to order against an RFQ.

Frequently asked questions

What is the breaking capacity of 3VA1132-5GF42-0AA0 at different voltages?

It delivers 187 kA at 240 VAC, 121 kA at 415 VAC, 75.6 kA at 440 VAC, and 17 kA at both 500 V and 690 VAC — covering most common distribution voltages in a single frame.

Where can I buy 3VA1132-5GF42-0AA0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

MPN