Skip to main content
Siemens 3VA1132-6EE42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-6EE42-0AA0-ZD00 Circuit Breaker, 70kA @ 415V

MPN3VA1132-6EE42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 4-pole MCCB, breaking capacity class H, Icu=70kA @ 415V, line protection TM220, ATFM, In=32A, overload Ir=22A...32A, short-circuit Ii=10 x In, N conductor unprotected, nut keeper kit, DC Power OEM variant for China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What the ratings mean for fit

The 3VA1132-6EE42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker from the Siemens 3VA1 series, configured as a line-protection device with a thermal-magnetic TM220 trip unit. Its headline rating is the 70 kA breaking capacity at 415 V (class H) — that means it can safely interrupt a fault current up to 70,000 A without rupturing, which is essential for high-fault installations like transformer secondaries or large motor control centers where the available short-circuit current is substantial. The adjustable overload protection (Ir = 22 A to 32 A) lets you fine-tune the continuous current setting to match the downstream load, while the fixed short-circuit pickup at 10 x In (320 A instantaneous) clears hard faults fast. The N conductor is unprotected, so this breaker is intended for 3-phase + N systems where you manage neutral protection separately or the neutral is not expected to carry fault current.

Deployment context

This breaker mounts in a standard panel or enclosure on a DIN rail or backplate; the 4-pole form factor fits IEC distribution boards and motor control centers. The 70 kA SCCR at 415 V means it can be used as a main or branch breaker in high-fault installations without cascading upstream — a key consideration for selectivity coordination studies. The nut keeper kit is a mechanical detail for the China DC Power OEM variant, ensuring the terminal hardware stays captive during vibration in DC power equipment.

Frequently asked questions

What is the breaking capacity of this breaker?

It has a breaking capacity of 70 kA at 415 V (class H), which means it can safely interrupt fault currents up to 70,000 A at that voltage.

How is the overload protection adjusted?

The thermal-magnetic TM220 trip unit allows overload current setting (Ir) from 22 A to 32 A, and the short-circuit pickup is fixed at 10 x In (320 A).

Where can I buy 3VA1132-6EE42-0AA0-ZD00 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA1132-6EE42-0AA0-ZD00