Skip to main content
Siemens 3VA1132-6EF32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-6EF32-0CA0 SENTRON MCCB, 32 A, 220 kA at 240

MPN3VA1132-6EF32-0CA0

Siemens SENTRON 3VA1132-6EF32-0CA0, 3-pole molded case circuit breaker, 32 A rated current, TM240 thermal-magnetic release, 220 kA breaking capacity at 240 VAC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1132-6EF32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11326EF320AA0

Ratings

3VA1132-6EF32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.13.1 W

Protection & Trip Unit

3VA1132-6EF32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1132-6EF32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1132-6EF32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1132-6EF32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1132-6EF32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB carries — and what it doesn't

The Siemens SENTRON 3VA1132-6EF32-0CA0 is a 3-pole molded case circuit breaker rated 32 A continuous at 40 °C through 50 °C, with a TM240 thermal-magnetic overcurrent release and an integrated undervoltage release (UVR). Breaking capacity is 220 kA at 240 VAC, derating to 154 kA at 415 VAC and 121 kA at 440 VAC — figures that place it in the high-interrupting category for industrial distribution. Rated insulation voltage is 800 V, and maximum power loss is 13.1 W.

Thermal derating and operating envelope

Rated current holds at 32 A from 40 °C to 50 °C, then drops to 31 A at 55–60 °C and 30 A at 65–70 °C — a shallow derating curve that gives panel builders headroom in warm enclosures. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Physical fit and release configuration

Measures 130 mm high, 76.2 mm wide, 70 mm deep — a standard SENTRON 3VA frame footprint that drops into existing 3VA panel layouts without re-drilling. Designed for line protection, with a TM240 thermal-magnetic release and an undervoltage release (UVR) as the auxiliary release. No ground-fault monitoring, no communication function, no trip indicator.

Frequently asked questions

Will the 3VA1132-6EF32-0CA0 drop into a panel specified around the 3VA1110-5EF32-0LA0?

Both share the same 3VA frame dimensions (130 mm H, 76.2 mm W, 70 mm D), so the physical footprint and DIN-rail mounting are identical — no rewiring of the busbar or enclosure cutout is needed for fit.

MPN
3VA1132-6EF32-0CA0