Siemens 3VA1132-6EF36-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-6EF36-0KC0 Circuit Breaker, 70kA @ 415V, 32A

MPN3VA1132-6EF36-0KC0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class H, Icu=70kA @ 415V, 3-pole, TM240 line protection, In=32A, overload Ir=22A...32A, shunt trip 220-250V DC / 208-277V AC, 2 auxiliary switches HQ, clamp connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

Siemens 3VA1132-6EF36-0KC0 — IEC Frame 160, 70kA Class H

The Siemens 3VA1132-6EF36-0KC0 is a 3-pole IEC circuit breaker from the 3VA1 series, built on a 160 A frame with breaking capacity class H — meaning it can interrupt 70 kA at 415 V AC without damage. That Icu rating places it in the high-break category for industrial distribution panels where fault currents are substantial, such as transformer secondaries or motor control center mains. Rated at In=32 A with a TM240 thermal-magnetic trip unit, the overload protection (Ir) is adjustable from 22 A to 32 A, and the instantaneous short-circuit pickup (Ii) is set at 5 to 10 times In. That adjustability lets you coordinate with downstream branch breakers or motor starters without swapping the entire device — useful for panel builders who need selectivity without oversizing.

Auxiliaries and Trip Accessories

The shunt trip allows emergency-off or remote-trip integration into a safety circuit or PLC-driven shutdown sequence. Clamp-type connections simplify panel wiring — no lug crimping needed for the main power terminals.

Frequently asked questions

What is the breaking capacity of this breaker?

Icu = 70 kA at 415 V AC, placing it in breaking capacity class H for the 3VA1 IEC frame 160 series.

Where can I buy 3VA1132-6EF36-0KC0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability.

What does the TM240 trip unit mean?

TM240 is a thermal-magnetic trip block: overload protection Ir is adjustable 22–32 A, and short-circuit pickup Ii is 5–10× In (160–320 A at the 32 A rating).

Does this breaker include a shunt trip?

Yes, it comes with a shunt trip (STL) rated for 220–250 V DC or 208–277 V AC, plus two HQ auxiliary switches.

MPN
3VA1132-6EF36-0KC0