Siemens 3VA1140-3EE42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-3EE42-0AA0 SENTRON MCCB, 40 A, 4-Pole, TM220

MPN3VA1140-3EE42-0AA0
Active

Siemens SENTRON 3VA1140-3EE42-0AA0, molded case circuit breaker, line protection, 4-pole, 40 A, TM220 thermal-magnetic trip unit, 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-3EE42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1140-3EE42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.8 W
3VA1140-3EE42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1140-3EE42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-3EE42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1140-3EE42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-3EE42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The interrupting capacity varies by system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

Temperature derating — the real continuous current

At 55 °C it derates to 39 A, at 60 °C still 39 A, at 65 °C it drops to 38 A, and at 70 °C it's 37 A. That's a gentle slope — only 3 A lost over a 25 °C rise — so the thermal margin is comfortable for most enclosed panel installations. If your enclosure runs hot (say, above 55 °C), plan for the 39 A ceiling rather than the nameplate 40 A.

It's a panel-mount MCCB — not a DIN-rail snap-on — so it bolts into a cutout or mounts on a backplate. Power loss is listed at 10.8 W maximum, which is modest for a 4-pole 40 A device and won't drive significant internal heating in a ventilated panel.

Voltage and application notes

The overcurrent release design is TM220, a thermal-magnetic type with fixed thermal and adjustable magnetic pickup; there is no ground-fault monitoring version and no N-conductor protection built in. Communication function is absent — this is a standalone breaker, not a metering or communicating device.

MPN
3VA1140-3EE42-0AA0