Siemens 3VA1140-3EE42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-3EE42-0AA0-ZD00 Circuit Breaker, 40A, 25kA @

MPN3VA1140-3EE42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, circuit breaker, breaking capacity class N, Icu=25kA @ 415V, 4-pole, line protection TM220, ATFM, In=40A, overload protection Ir=28A...40A, short-circuit protection Ii=10 x In, N conductor unprotected, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

This Siemens 3VA1140-3EE42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker with a 40 A continuous rating and a 25 kA interrupting capacity at 415 V. The breaking capacity class N puts it in the standard-duty range for general distribution panels — not the high-fault gear you'd spec for a transformer secondary, but plenty for most branch circuits in a commercial or light industrial plant. The thermal-magnetic trip unit (TM220, ATFM) provides adjustable overload protection from 28 A to 40 A via the Ir dial, and fixed short-circuit protection at 10 times the In rating. The N conductor is unprotected on this variant, meaning the neutral bar passes straight through without a pole or trip. That's common for 3-phase + N distribution where the neutral only carries unbalanced current and doesn't need its own overcurrent device. The nut keeper kit is a detail for the DC Power OEM build in China — keeps the terminals from backing off under vibration on a DC bus.

The 4-pole footprint takes up the same width as four single-pole breakers ganged together, so factor that into your enclosure fill calculations. The nut keeper kit is already on the terminals, which saves a step if you're torquing down DC bus bars. The TM220 thermal unit is ambient-compensated, but if your panel runs above 40 °C ambient, you'll want to derate the Ir setting per the standard IEC 60947-2 thermal curve. In a crowded enclosure with drives or transformers dumping heat, that's a real consideration — the breaker might trip earlier than the dial setting suggests.

Frequently asked questions

What is the interrupting rating of this breaker?

The 3VA1140-3EE42-0AA0-ZD00 has a 25 kA interrupting capacity at 415 V (breaking capacity class N).

What does the N conductor unprotected mean on this breaker?

It means the neutral conductor passes through the breaker without a pole or overcurrent trip — standard for 3-phase + N distribution where the neutral carries only unbalanced current.