Siemens 3VA1140-3EF32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-3EF32-0CA0 SENTRON MCCB, 40 A, 3-Pole, Line

MPN3VA1140-3EF32-0CA0

Siemens SENTRON 3VA1140-3EF32-0CA0, molded case circuit breaker, 3-pole, 40 A, line protection, TM240 release, undervoltage release, 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-3EF32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1140-3EF32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA
3VA1140-3EF32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1140-3EF32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-3EF32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1140-3EF32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-3EF32-0CA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1140-3EF32-0CA0 is a 3-pole molded case circuit breaker rated for a continuous current of 40 A at ambient temperatures up to 50 °C, with a thermal-magnetic TM240 overcurrent release and an integrated undervoltage release (UVR). The interrupting ratings are substantial: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V.

Above that, it derates linearly: 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. The unit has no auxiliary contacts, no communication function, no phase-failure detection, and no ground-fault monitoring. If you need those, you'll add external modules or choose a different variant.

Mechanical and dimensional fit

The depth of 70 mm means it will clear most shallow enclosures, but verify the gland plate clearance if the breaker is mounted near the back wall. That's typical for a line-protection MCCB — it's not a contactor meant for frequent switching, but it handles routine on-off cycles for maintenance or isolation without wearing out prematurely.

Frequently asked questions

What are the key interrupting ratings for this MCCB?

The breaker is rated for 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. These are the maximum fault currents it can safely interrupt at those voltages.

What is the rated continuous current and how does it derate with temperature?

The rated continuous current is 40 A at ambient temperatures up to 50 °C. Above that, it derates to 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C.

Where can I buy the 3VA1140-3EF32-0CA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN