Skip to main content
Siemens 3VA1140-3EF32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-3EF32-0KA0 SENTRON MCCB, 40 A, 3-Pole, 75.6

MPN3VA1140-3EF32-0KA0

Siemens SENTRON 3VA1140-3EF32-0KA0, molded case circuit breaker, 3-pole, 40 A rated continuous current, TM240 thermal-magnetic overcurrent release, shunt trip, 75.6 kA at 240 V interrupting capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-3EF32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1140-3EF32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA
3VA1140-3EF32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1140-3EF32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-3EF32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1140-3EF32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-3EF32-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The TM240 thermal-magnetic overcurrent release handles both overload and short-circuit protection without an external relay — a common choice where adjustable electronic trip is not required. Interrupting capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. These figures govern SCCR coordination downstream: at 415 V, for example, the breaker clears a 52.5 kA fault without upstream reinforcement, which simplifies panel design in 400 V distribution. The auxiliary release order code is 3VA9688-0BL33. No auxiliary contacts, undervoltage release, or communication function are fitted, so add-on blocks are needed if those features are required.

The breaker holds its 40 A rating through 50 °C ambient (–). Above that, current must be derated: 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C (–). The 76.2 mm width is a standard 3-pole MCCB footprint — it occupies three 25.4 mm (1-inch) module positions on a DIN rail or panel-mount base.

Frequently asked questions

What is the interrupting capacity of 3VA1140-3EF32-0KA0 at 415 V?

52.5 kA at 415 V. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 10.5 kA.

Where can I buy 3VA1140-3EF32-0KA0?

This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ.

Does 3VA1140-3EF32-0KA0 include a shunt trip?

Yes, it is designed with a shunt trip release (STL). The auxiliary release order code is 3VA9688-0BL33. No undervoltage release or auxiliary contacts are included.

MPN
3VA1140-3EF32-0KA0