Skip to main content
Siemens 3VA1140-3EF36-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-3EF36-0HH0 SENTRON MCCB, 40 A, 3-Pole, 75.6

MPN3VA1140-3EF36-0HH0

Siemens SENTRON 3VA1140-3EF36-0HH0, molded case circuit breaker, 3-pole, 40 A rated at 40 °C, 75.6 kA breaking capacity at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1140-3EF36-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11403EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1140-3EF36-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.8 W

Protection & Trip Unit

3VA1140-3EF36-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1140-3EF36-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1140-3EF36-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1140-3EF36-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1140-3EF36-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1140-3EF36-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 40 A across the 40 °C to 50 °C band and derating to 37 A at 70 °C. Its interrupting capacity hits 75.6 kA at 240 V AC, 52.5 kA at 415 V, and 11.9 kA at 690 V — figures that govern selectivity coordination in a distribution panel. The 800 V rated insulation voltage gives headroom for 690 V line-to-line systems without derating the dielectric margin.

Breaking capacity and selectivity

At 415 V the 52.5 kA breaking capacity places this MCCB in the high-interrupting category for a 40 A frame — it clears faults up to that level without upstream fuse backup in most panel designs. The 32 kA at 440 V and 11.9 kA at 690 V track the expected voltage-derate curve; selectivity tables from the SENTRON manual should be consulted for coordination with upstream 3VA breakers or SIRIUS fuses.

Auxiliary and release configuration

Factory-fitted with 2 auxiliary switches plus a trip alarm switch (HQ) and a shunt trip release (STL). The shunt trip allows remote tripping from a PLC safety output or emergency-stop circuit. The auxiliary contacts report breaker position to the control system. No undervoltage release and no ground-fault monitoring on this variant — those functions are available on other 3VA order codes if needed.

Thermal derating and power loss

Rated 40 A from 40 °C through 50 °C ambient; drops to 39 A at 55–60 °C and 38 A at 65 °C, then 37 A at 70 °C (–). Maximum power loss is 10.8 W — relevant for enclosure heat rise calculations when grouping multiple breakers. Operating temperature range -25 °C to +70 °C; storage range -40 °C to +80 °C.

Lifecycle and sourcing

The lifecycle stage is marked as current production. This is an active Siemens SENTRON 3VA catalog line — no phase-out notice on record. Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Frequently asked questions

What auxiliary switches and releases come fitted on this MCCB?

It ships with 2 auxiliary switches plus 1 trip alarm switch (HQ) and a shunt trip release (STL). No undervoltage release or ground-fault monitoring is included on this variant.

MPN
3VA1140-3EF36-0HH0