Skip to main content
Siemens 3VA1140-4EF32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-4EF32-0AB0 SENTRON MCCB, 40 A, 121 kA at 240

MPN3VA1140-4EF32-0AB0

Siemens SENTRON 3VA1140-4EF32-0AB0, molded case circuit breaker, line protection, 3-pole, 40 A rated continuous current Iu, TM240 thermal-magnetic trip, interrupting capacity 121 kA at 240 V, 75.6 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-4EF32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1140-4EF32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1140-4EF32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1140-4EF32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-4EF32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1140-4EF32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-4EF32-0AB0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA line protection MCCB — 40 A, high interrupting capacity

It carries a rated continuous current Iu of 40 A with a flat thermal derating curve — still rated 40 A at 50 °C, dropping only to 36 A at 70 °C — so it holds its full rating in most ventilated enclosures without oversizing. Interrupting capacity is the headline: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. That 121 kA figure at 240 V puts it well above typical 65 kA or 100 kA MCCBs — useful where fault current is high (large transformer, tight impedance path) and you need to avoid cascading failure upstream. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a compact 3-pole footprint that fits standard Siemens 3VA panel cutouts. Front protection is IP40, so it handles typical panel environments but not washdown.

Mounts in a standard SENTRON 3VA panel cutout — 76.2 mm width on a 3-pole footprint. The 70 mm depth leaves clearance for rear busbar connections and wiring troughs. Two auxiliary switches (HP type) are built in for remote status indication; no additional aux block needed for basic open/closed signalling.

Frequently asked questions

What is the depth of 3VA1140-4EF32-0AB0?

70 mm depth, with a width of 76.2 mm and height of 130 mm.

MPN