Siemens 3VA1140-4EF32-0CC0 SENTRON MCCB, 40 A, 3-Pole, 121 k

MPN3VA1140-4EF32-0CC0

Siemens SENTRON 3VA1140-4EF32-0CC0, molded case circuit breaker, 3-pole, 40 A rated, TM240 overcurrent release, 121 kA at 240 V, undervoltage release, 2 auxiliary switches HQ, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-4EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1140-4EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1140-4EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1140-4EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-4EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1140-4EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-4EF32-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Line protection MCCB with high interrupting capacity

The interrupting capacity reaches 121 kA at 240 V, 75.6 kA at 415 V, and 52.5 kA at 440 V — enough to handle high-fault utility feeds without cascading upstream. No communication module, phase-failure detection, or ground-fault monitoring is built in — this is a straightforward line-protection device, not a power-monitoring breaker. The auxiliary trip is ordered separately as 3VA9608-0BB24.

Above that, derating is gradual: 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint for DIN-rail or screw-mount panel integration. No trip indicator is fitted, so visual status relies on the auxiliary switches or handle position.

Frequently asked questions

Where can I buy 3VA1140-4EF32-0CC0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and current pricing.

What is the interrupting capacity of 3VA1140-4EF32-0CC0 at 415 V?

At 415 V the interrupting capacity is 75.6 kA. At 240 V it is 121 kA, at 440 V it is 52.5 kA, and at 690 V it is 11.9 kA.

Does 3VA1140-4EF32-0CC0 include an undervoltage release?

Yes, it includes an integrated undervoltage release (UVR) as standard. It also has two HQ auxiliary switches for status feedback.

MPN
3VA1140-4EF32-0CC0