Siemens 3VA1140-5EE36-0AA0 SENTRON MCCB, 40 A, 3-Pole, 187 k

MPN3VA1140-5EE36-0AA0
Active

Siemens SENTRON 3VA1140-5EE36-0AA0, 3-pole molded case circuit breaker, 40 A, TM220 thermal-magnetic trip, 187 kA interrupting at 240 VAC, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-5EE36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1140-5EE36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.8 W
3VA1140-5EE36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1140-5EE36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-5EE36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1140-5EE36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-5EE36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1140-5EE36-0AA0 — 40 A MCCB, Line Protection, TM220 Trip Unit

The Siemens SENTRON 3VA1140-5EE36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 40 A across its full ambient temperature range from 40 °C to 50 °C, with minor derating to 37 A at 70 °C. Interrupting capacity reaches 187 kA at 240 VAC, 121 kA at 415 VAC, and 75.6 kA at 440 VAC, with a floor of 17 kA at 500 V and 690 VAC — sufficient for high-fault panelboards and main distribution switchboards where SCCR headroom is critical.

Mounting and Integration — DIN-Rail Panel Fit

The breaker occupies a 76.2 mm wide, 130 mm tall, 70 mm deep footprint — three standard 25 mm DIN-rail module widths — and mounts directly onto a DIN rail in the distribution panel. Front face carries an IP40 protection rating, meaning tools and fingers are kept out, but the enclosure is not sealed against moisture — suitable for indoor panel installation only.

Frequently asked questions

What trip unit does the 3VA1140-5EE36-0AA0 use?

It uses a TM220 thermal-magnetic overcurrent release with fixed trip settings — no adjustment dials — designed for line protection in distribution circuits.