Siemens 3VA1140-5EF36-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-5EF36-0DA0 SENTRON MCCB, 40 A, 3-Pole, 187 k

MPN3VA1140-5EF36-0DA0

Siemens SENTRON 3VA1140-5EF36-0DA0, 3-pole molded case circuit breaker, 40 A rated continuous current, TM240 thermal-magnetic release, 187 kA interrupting at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1140-5EF36-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1140-5EF36-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA

Protection & Trip Unit

3VA1140-5EF36-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1140-5EF36-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1140-5EF36-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1140-5EF36-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1140-5EF36-0DA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Line protection MCCB with TM240 release

The Siemens SENTRON 3VA1140-5EF36-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 40 A continuous current at up to 50 °C ambient, with the TM240 thermal-magnetic overcurrent release. It carries an interrupting capacity of 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — figures that cover high-fault utility feeds and transformer secondaries without cascading upstream. The 800 V rated insulation voltage (Ui) suits it for 690 V line-to-line systems where the 17 kA interrupting rating applies. This is a line-protection variant, not a motor-protector; the TM240 release provides fixed thermal and magnetic trip thresholds for feeder and distribution duty.

SCCR headroom and selectivity planning

For a site electrical engineer coordinating selectivity, the 187 kA at 240 V and 121 kA at 415 V ratings mean this MCCB can be applied downstream of a transformer with minimal let-through energy — the high interrupting capacity reduces the need for current-limiting fuses upstream. The TM240 release has no electronic adjustment, so coordination studies rely on the fixed thermal-magnetic curve; the manufacturer publishes time-current curves for the 3VA series. The 15000-cycle latching endurance is typical for a distribution MCCB — adequate for infrequent switching, not for motor-starting duty cycles.

Panel integration and mounting

The 3VA1140-5EF36-0DA0 measures 76.2 mm wide, 130 mm high, and 70 mm deep. It mounts on a DIN rail or directly to a backplate via the screw terminals. The IP40 front protection means it is protected against tools and wires >1 mm — suitable for enclosed panel installation, not for washdown environments. The undervoltage release (UVR) is fitted as standard, so the breaker trips on loss of control voltage; the auxiliary trip accessory (3VA9608-0BB25) is available but not included. No auxiliary contacts are present on this variant, so status feedback to a PLC requires an add-on module.

Thermal derating and ambient limits

The 40 A rating holds flat from 40 °C to 50 °C. Above 50 °C, derating applies: 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C (–). The operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. For a panel builder, this means the breaker can be placed near heat-generating components (drives, transformers) as long as the ambient at the breaker's inlet stays within the derated current. The TM240 release's thermal element responds to self-heating plus ambient — a panel with poor airflow at 60 °C must be loaded to no more than 37.6 A.

Frequently asked questions

Where can I buy 3VA1140-5EF36-0DA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the interrupting capacity of 3VA1140-5EF36-0DA0 at 415 V?

At 415 V, the interrupting capacity is 121 kA.

Does 3VA1140-5EF36-0DA0 include an undervoltage release?

Yes, it is fitted with an undervoltage release (UVR) as standard.

What is the rated continuous current of 3VA1140-5EF36-0DA0?

The rated continuous current (Iu) is 40 A, holding flat up to 50 °C ambient.

MPN
3VA1140-5EF36-0DA0