Siemens 3VA1140-6EE36-0AA0 SENTRON MCCB, 40 A, 3-Pole, 220 k

MPN3VA1140-6EE36-0AA0
Active

Siemens SENTRON 3VA1140-6EE36-0AA0, Molded case circuit breaker, 3-pole, 40 A, TM220 release, breaking capacity 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, 17 kA at 500/690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1140-6EE36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1140-6EE36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.8 W

Protection & Trip Unit

3VA1140-6EE36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1140-6EE36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1140-6EE36-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1140-6EE36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1140-6EE36-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1140-6EE36-0AA0 — 40 A MCCB with TM220 release

The Siemens SENTRON 3VA1140-6EE36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 40 A. It is fitted with a TM220 thermal-magnetic overcurrent release — the TM220 designation means the thermal (overload) element is fixed at 40 A, while the magnetic (short-circuit) pickup is adjustable up to 400 A (10× Iu), giving you a wide coordination window for motor or transformer inrush without nuisance tripping.

Breaking capacity across the voltage range

This MCCB delivers 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — numbers that put it in the high-interrupting class for industrial distribution. At 500 V and 690 V it still holds 17 kA, which covers most motor-circuit fault levels in 480/600 V class panels. The IEC 60947-2 standard these ratings are built to means the breaker can safely clear a bolted fault up to those levels without welding contacts or venting arc gas into the enclosure.

Thermal derating and panel integration

The 40 A rating holds flat from 40 °C to 50 °C, then derates gradually: 39 A at 55–60 °C, 38 A at 65 °C, and 37 A at 70 °C. In a sealed panel with multiple breakers ganged together, that derating curve is what you use for the fill-factor calculation — the full 40 A only applies if ambient inside the enclosure stays under 50 °C. Front IP40 protects against tools and wires, not hose-down; mount it in a clean indoor MCC or panelboard, not a washdown zone.

Lifecycle and sourcing

The lifecycle stage is marked as current production — this is an active catalog number in the SENTRON 3VA platform, not a phase-out or NRND line. The 3VA series succeeded the 3VL family and is the standard MCCB offering from Siemens for panelboard and distribution applications. Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Dimensions and physical fit

The breaker measures 130 mm high, 76.2 mm wide (3 inches — standard MCCB footprint for 3-pole 40 A frame), and 70 mm deep. That 70 mm depth is shallower than many 40 A MCCBs in the 3VA family, which helps when the gland plate or backplane clearance is tight. The width matches the 3-pole cutout in most Siemens panelboard interiors; no adapter plate needed.

Frequently asked questions

Where can I buy 3VA1140-6EE36-0AA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the breaking capacity of 3VA1140-6EE36-0AA0 at 240 V?

220 kA at 240 V, which covers high-fault utility feeds and transformer secondaries. At 415 V it is 154 kA, at 440 V 121 kA, and at 500/690 V it holds 17 kA.

What does the TM220 release mean on this MCCB?

TM220 means a fixed 40 A thermal element for overload protection and an adjustable magnetic short-circuit pickup up to 400 A (10× Iu). You set the magnetic threshold via the dial on the front face to coordinate with downstream loads.

Will 3VA1140-6EE36-0AA0 fit a panel designed for 5SQ2370-2YA05?

The 3VA1140-6EE36-0AA0 is a 3-pole 40 A MCCB on a 76.2 mm wide footprint. The 5SQ2370-2YA series are different manufacturer part numbers; physical interchange depends on the panelboard cutout and bus bar spacing. Verify the mounting pattern and line/load connection layout against the existing panel schedule before specifying as a drop-in replacement.

MPN
3VA1140-6EE36-0AA0