Siemens 3VA1140-6EF32-0AD0 SENTRON MCCB, 40 A, 220 kA at 240

MPN3VA1140-6EF32-0AD0

Siemens SENTRON 3VA1140-6EF32-0AD0, molded case circuit breaker, 3-pole, rated continuous current Iu 40 A, TM240 thermal-magnetic release, breaking capacity 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, 17 kA at 690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-6EF32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1140-6EF32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1140-6EF32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1140-6EF32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-6EF32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1140-6EF32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-6EF32-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its breaking capacity hits 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — these figures mean it can safely interrupt fault currents up to those levels without upstream cascading, which is the deciding factor for high-fault panels near large transformers or utility feeds.

The 40 A rating holds flat from 40 °C through 50 °C, then derates to 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. If the panel ambient runs above 50 °C, the continuous load must be backed off accordingly — the 36 A floor at 70 °C still leaves headroom for a 30 A continuous load, but a full 40 A draw at 70 °C would nuisance-trip. The 76.2 mm width and 70 mm depth (130 mm height) fit a standard 3-pole MCCB footprint on the DIN rail or panel-mount plate; the IP40 front protection keeps dust out of the enclosure face.

Frequently asked questions

What is the breaking capacity of 3VA1140-6EF32-0AD0 at 415 V?

154 kA at 415 V, which is the typical three-phase industrial voltage in many regions; the part also carries 220 kA at 240 V, 121 kA at 440 V, and 17 kA at 690 V.

Where can I buy 3VA1140-6EF32-0AD0?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

Does 3VA1140-6EF32-0AD0 include auxiliary contacts?

Yes, it comes with 3 auxiliary switches HQ for status signaling, which can be wired to a PLC input or indicator lamp.

MPN