Skip to main content
Siemens 3VA1140-6EF36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1140-6EF36-0CC0 SENTRON MCCB, 40A, 3-Pole, 220 kA

MPN3VA1140-6EF36-0CC0

Siemens SENTRON 3VA1 molded case circuit breaker, 3VA1140-6EF36-0CC0, 3-pole, 40 A (40 °C), 220 kA breaking capacity at 240 V AC, line protection, with undervoltage release and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1140-6EF36-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11406EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1140-6EF36-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.13.3 W
3VA1140-6EF36-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1140-6EF36-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1140-6EF36-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1140-6EF36-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1140-6EF36-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It's a 3-pole unit carrying 40 A continuously at 40 °C ambient, with the full rated current holding steady up to 50 °C before a gentle derating curve kicks in — 39 A at 55–60 °C, 38 A at 65 °C, 37 A at 70 °C. That thermal profile matters when you're packing breakers into a warm enclosure and need to know your headroom without guessing. Breaking capacity is where this breaker earns its keep: 220 kA at 240 V AC, 154 kA at 415 V, 121 kA at 440 V, and still 17 kA at 500 V and 690 V. That's high-fault rated for a 40 A frame — useful downstream of a large transformer or on a high-capacity bus where a standard MCCB would need upstream fuses for coordination.

Built-in accessories and panel fit

The two aux switches give you status feedback (open/closed) for the PLC or annunciator without adding external interface relays. Dimensions are 76.2 mm wide, 130 mm tall, 70 mm deep — a 3-pole MCCB that fits standard distribution panel mounting.

Frequently asked questions

Where can I buy 3VA1140-6EF36-0CC0 and get a price?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

What is the breaking capacity of 3VA1140-6EF36-0CC0 at 240 V?

At 240 V AC the breaking capacity is 220 kA. At 415 V it's 154 kA, at 440 V it's 121 kA, and at 500 V / 690 V it's 17 kA.

Does the 3VA1140-6EF36-0CC0 include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) factory-fitted, plus two auxiliary switches (HQ design) for status feedback.

MPN
3VA1140-6EF36-0CC0