Skip to main content
Siemens 3VA1150-3EF32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-3EF32-0KH0 SENTRON MCCB, 50 A, TM240, 75.6 k

MPN3VA1150-3EF32-0KH0

Siemens SENTRON 3VA1150-3EF32-0KH0, molded case circuit breaker, line protection, 3-pole, 50 A (Iu), TM240 thermal-magnetic release, 75.6 kA interrupting at 240 V, shunt trip, 2 aux + 1 alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-3EF32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1150-3EF32-0KH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA

Protection & Trip Unit

3VA1150-3EF32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1150-3EF32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-3EF32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1150-3EF32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-3EF32-0KH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this MCCB delivers — and where the ratings matter

The 3VA1150-3EF32-0KH0: Breaking capacity is the headline: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. That's a lot of fault-clearing muscle for a 50 A frame — it'll ride through high-fault scenarios without upstream coordination headaches, provided your SCCR study confirms the numbers. Thermal derating is honest: full 50 A holds up through 50 °C, then drops to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. If your panel ambient runs hot, size the load side accordingly — don't assume full rating at 65 °C. Footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — standard SENTRON 3VA form factor. It'll drop into existing panel layouts without re-drilling the mounting plate.

Integrated accessories and release options

This unit ships with a shunt trip (STL) auxiliary release (design code 3VA9688-0BL33) and a 2-auxiliary-switch plus 1-trip-alarm-switch HQ contact block. The TM240 overcurrent release is thermal-magnetic — fixed thermal, fixed magnetic — so no field-adjustable trip curves, but it's reliable and coordination-simple. No undervoltage release, no communication module, no ground-fault monitoring, no phase-failure detection — this is a straight line-protection breaker. If you need those functions, you're looking at a different 3VA variant. Front IP40 rating means it's splash-protected from the front in a closed panel; not for open washdown zones. Storage range -40 °C to 80 °C, operating -25 °C to 70 °C.

Panel integration and wiring notes

Mounts on a standard DIN rail or direct screw-mount plate — 76.2 mm width fits a 3-module footprint. The 70 mm depth leaves room behind the gland plate for cable bends. Rated insulation voltage 800 V, so it's comfortable on 480/277 V and 600 V systems. Latching endurance rated at 15,000 operations — mechanical, not electrical.

Sourcing and lifecycle posture

Lifecycle is confirmed active (current production). No PCN, no phase-out notice. This part is sourced to order through independent distribution — submit an RFQ for current availability and pricing.

Frequently asked questions

Does this breaker include a shunt trip or undervoltage release?

It includes a shunt trip (STL) auxiliary release. No undervoltage release is fitted.

What auxiliary contacts come with this unit?

Two auxiliary switches plus one trip alarm switch (HQ version).

MPN
3VA1150-3EF32-0KH0