Skip to main content
Siemens 3VA1150-3GE42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-3GE42-0AA0 SENTRON MCCB, 50 A, 4-Pole, 75.6

MPN3VA1150-3GE42-0AA0
Active

Siemens SENTRON 3VA1150-3GE42-0AA0, molded case circuit breaker, 4-pole, 50 A (40 °C), TM220 release, 75.6 kA at 240 V, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-3GE42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1150-3GE42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.14.6 W

Protection & Trip Unit

3VA1150-3GE42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1150-3GE42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-3GE42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1150-3GE42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-3GE42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Line protection MCCB for panel builders

The Siemens SENTRON 3VA1150-3GE42-0AA0 is a 4-pole molded case circuit breaker rated 50 A continuous at 40 °C, with a TM220 thermal-magnetic release for line protection. Its 75.6 kA interrupting capacity at 240 V gives headroom for high-fault panel applications, and the 800 V rated insulation voltage (Ui) suits it for 480 V and 600 V distribution systems. The IP40 front protection means it's fit for enclosed panel mounting — not exposed washdown areas.

Breaking capacity across voltages

This MCCB delivers 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That curve tells you the part is sized for high-fault 240 V secondary panels, but still holds 11.9 kA at 690 V — enough for most industrial motor branch circuits. The 600 V DC max rated operational voltage (Ue with DC) also opens the door for DC bus protection in VFD lineups.

Thermal derating and power loss

Rated 50 A from 40 °C through 50 °C, then derates to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. Maximum power loss is 14.6 W — relevant for thermal budgeting inside a sealed enclosure. Operating range is -25 °C to 70 °C; storage range -40 °C to 80 °C.

Panel fit and dimensions

Dimensions are 70 mm depth, 101.6 mm width, 130 mm height — a standard 4-pole MCCB footprint that mounts on a DIN rail or panel-mount base. The 100% N-conductor protection design means the neutral pole is fully rated, not reduced, so it handles the same continuous current as the phase poles.

Frequently asked questions

What is the breaking capacity of 3VA1150-3GE42-0AA0 at 240 V?

It interrupts 75.6 kA at 240 V, with 52.5 kA at 415 V and 11.9 kA at 690 V.

What overcurrent release does this MCCB use?

It uses a TM220 thermal-magnetic release — a fixed-trip design with thermal protection for overloads and magnetic for short circuits, no electronic adjustment.

Where can I buy 3VA1150-3GE42-0AA0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What compliance documentation is available for 3VA1150-3GE42-0AA0?

As a Siemens SENTRON MCCB, it carries IEC 60947-2 certification. RoHS and REACH declarations are standard with the brand; UL listing is typical for this series but should be confirmed per the specific variant.

MPN
3VA1150-3GE42-0AA0