Siemens 3VA1150-3GF46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-3GF46-0AA0 SENTRON MCCB, 50 A, 4-Pole, TM240

MPN3VA1150-3GF46-0AA0
Active

Siemens SENTRON 3VA1150-3GF46-0AA0, molded case circuit breaker, 4-pole, 50 A, TM240 thermal-magnetic release, breaking capacity 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-3GF46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1150-3GF46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.14.6 W

Protection & Trip Unit

3VA1150-3GF46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1150-3GF46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-3GF46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1150-3GF46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-3GF46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this MCCB is and what it does

The Siemens 3VA1150-3GF46-0AA0 is a SENTRON-series molded case circuit breaker (MCCB) rated for line protection in distribution panels. It carries a continuous 50 A at 40 °C through 50 °C, derating to 45 A at 70 °C — so the full rating holds across most common panel ambient conditions without a de-rate calculation. Four poles give you the ability to switch all three phases plus neutral in a single enclosure, which simplifies wiring in 3-phase+neutral distribution and avoids a separate neutral disconnect. The TM240 thermal-magnetic release handles the overload and short-circuit protection curves; there's no undervoltage release, no ground-fault monitoring, and no communication module on this variant.

Breaking capacity — where it clears faults

The interrupting ratings span the voltage range you'd expect in industrial distribution: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That 52.5 kA at 415 V is the figure most panel builders will check first for European 400 V-class systems — it gives headroom above the typical 25–36 kA prospective fault current in most commercial switchboards.

Panel fit and mounting

Dimensions are 70 mm deep, 101.6 mm wide, 130 mm tall — a 4-pole MCCB that fits standard SENTRON mounting feet on a DIN rail or panel-mount backplate. The IP40 front protection means it's suited for enclosed distribution boards where the door provides the final seal; not for washdown zones.

Frequently asked questions

How do I get current pricing and availability for 3VA1150-3GF46-0AA0?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What is 3VA1150-3GF46-0AA0's listed depth (70 mm) on this component line?

The listed depth is 70 mm (2.76 in), with a width of 101.6 mm (4 in) and height of 130 mm (5.12 in). This is a standard 4-pole MCCB footprint for SENTRON panel mounting.

What compliance documentation does this brand provide for 3VA1150-3GF46-0AA0?

As a Siemens SENTRON product, this MCCB carries the standard CE marking for the European market. RoHS and REACH compliance documentation is available from Siemens' technical documentation portal for the 3VA series.

MPN
3VA1150-3GF46-0AA0