Siemens 3VA1150-4EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-4EF32-0DH0 SENTRON MCCB, 50 A, 3-Pole, 121 k

MPN3VA1150-4EF32-0DH0

Siemens SENTRON 3VA1150-4EF32-0DH0, molded case circuit breaker, 3-pole, 50 A, line protection, interrupting rating 121 kA at 240 V AC, with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-4EF32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11504EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1150-4EF32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.1 W

Protection & Trip Unit

3VA1150-4EF32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1150-4EF32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-4EF32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1150-4EF32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-4EF32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB delivers — and what the ratings mean for your panel

The Siemens SENTRON 3VA1150-4EF32-0DH0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current of 50 A at 40 °C and derating to 45 A at 70 °C (cites:,). Its interrupting capacity reaches 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V — figures that define the maximum fault current the breaker can safely clear at each voltage level without upstream coordination failure (cites:,). The rated insulation voltage is 800 V, confirming its suitability for 690 V line-to-line systems (cites:). The breaker ships with an undervoltage release (UVR) and a complement of two auxiliary switches plus one trip alarm switch HQ — factory-fitted, so no field retrofit of the UVR is needed (cites:,). A trip indicator is present for quick fault identification during commissioning or troubleshooting (cites:). Panel integration is straightforward: the breaker occupies a 76.2 mm width, 130 mm height, and 70 mm depth — a standard SENTRON 3VA footprint that fits existing DIN-rail or mounting-plate layouts without re-drilling (cites:,).

Compliance and documentation

As a SENTRON-series MCCB, the 3VA1150-4EF32-0DH0 is designed to meet IEC 60947-2 and UL 489 standards. The manufacturer provides a declaration of conformity covering the Low Voltage Directive and relevant harmonized standards. RoHS and REACH compliance documentation is included in the product's technical file — request it with your RFQ for audit-ready traceability.

Frequently asked questions

How do I get current pricing and availability for 3VA1150-4EF32-0DH0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; this part is sourced to order through independent distribution channels.

What is the interrupting rating of 3VA1150-4EF32-0DH0 at different voltages?

The breaker is rated 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V (cites:,).

Does 3VA1150-4EF32-0DH0 include an undervoltage release?

Yes, it is factory-fitted with an undervoltage release (UVR) plus two auxiliary switches and one trip alarm switch HQ (cites:,).

MPN
3VA1150-4EF32-0DH0