Skip to main content
Siemens 3VA1150-4EF36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-4EF36-0AB0 SENTRON MCCB, 50 A, 3-Pole, 121 k

MPN3VA1150-4EF36-0AB0

Siemens SENTRON 3VA1150-4EF36-0AB0, molded case circuit breaker, 3-pole, 50 A rated continuous current, TM240 overcurrent release, 121 kA at 240 V, 75.6 kA at 415 V, 2 auxiliary switches HP.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-4EF36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA1150-4EF36-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA

Protection & Trip Unit

3VA1150-4EF36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1150-4EF36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-4EF36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1150-4EF36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-4EF36-0AB0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1150-4EF36-0AB0 is a 3-pole molded case circuit breaker (MCCB) rated for 50 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity reaches 121 kA at 240 V and 75.6 kA at 415 V, making it suitable for high-fault-current distribution panels where selectivity with upstream breakers is required.

Breaking capacity and thermal derating

At 440 V the interrupting rating is 52.5 kA; at 690 V it drops to 11.9 kA — the voltage-dependent curve is typical for MCCBs and governs where this breaker can be applied in a 690 V system. The rated continuous current holds at 50 A up to 50 °C ambient, then derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. Panel builders should account for the derating when the breaker is enclosed or mounted near other heat sources.

Physical fit and auxiliary contacts

The breaker measures 70 mm deep, 76.2 mm wide, and 130 mm high — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. It ships with 2 auxiliary switches (HP type) factory-installed, which provide status feedback to a PLC or indication circuit without needing a separate accessory. The front face carries an IP40 protection rating, adequate for enclosed panel use but not for washdown environments.

Frequently asked questions

What is the breaking capacity of 3VA1150-4EF36-0AB0 at 415 V?

At 415 V the interrupting rating is 75.6 kA, which provides ample fault-clearing headroom for most industrial distribution panels.

Where can I buy 3VA1150-4EF36-0AB0 and how is it quoted?

This MCCB is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ with your target quantity and delivery window.

Will 3VA1150-4EF36-0AB0 drop into a panel specified around 3VA1010-4ED32-0AC0?

The 3VA1150-4EF36-0AB0 uses the same 3-pole MCCB footprint (70 mm deep, 76.2 mm wide, 130 mm high) as the 3VA1010 frame, so it will physically fit the same mounting holes and bus connections. However, the higher continuous current (50 A vs. the 3VA1010's lower rating) and different trip curve (TM240) mean the upstream protection coordination must be recalculated.

MPN
3VA1150-4EF36-0AB0