Skip to main content
Siemens 3VA1150-4EF36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-4EF36-0CH0 SENTRON MCCB, 50 A, 3-Pole, 121 k

MPN3VA1150-4EF36-0CH0

Siemens SENTRON 3VA1150-4EF36-0CH0, molded case circuit breaker, 3-pole, 50 A (40 °C), breaking capacity 121 kA at 240 V, 75.6 kA at 415 V, TM240 release, undervoltage release, auxiliary contacts 2+1 HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1150-4EF36-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1150-4EF36-0CH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1150-4EF36-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1150-4EF36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1150-4EF36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1150-4EF36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1150-4EF36-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1150-4EF36-0CH0 SENTRON MCCB – 50 A, 3-Pole, 121 kA Breaking Capacity

Its interrupting capacity hits 121 kA at 240 V and 75.6 kA at 415 V — numbers that matter when you're clearing high-fault faults downstream of a transformer or feeding a motor control center. That 50 A rating holds steady through 50 °C, then derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C — so if your panel runs hot near the top of the enclosure, you lose about 1 A per 5 °C above 50 °C. Plan your load margin accordingly.

Key Ratings & What They Mean

The TM240 overcurrent release is a thermal-magnetic trip unit — thermal for overload protection (adjustable), magnetic for short-circuit. That's useful for safety circuits or coordinated shutdown sequences.

Physical Fit & Panel Integration

Frequently asked questions

Will 3VA1150-4EF36-0CH0 drop into a panel specified around 3VA1112-5EF32-0CA0?

Both are 3-pole SENTRON MCCBs with similar physical dimensions (130 mm height, 76.2 mm width, 70 mm depth), so the footprint is compatible. However, the 3VA1150-4EF36-0CH0 carries a 50 A rating and a TM240 release, while the 3VA1112-5EF32-0CA0 is a different variant — verify the load current and trip curve before substituting.

MPN
3VA1150-4EF36-0CH0