Skip to main content
Siemens 3VA1150-4GF46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-4GF46-0AA0 SENTRON MCCB, 4P, 50A, TM240, 121

MPN3VA1150-4GF46-0AA0
Active

Siemens SENTRON 3VA1150-4GF46-0AA0, 4-pole molded case circuit breaker, 50 A rated continuous current, TM240 thermal-magnetic trip unit, interrupting capacity 121 kA at 240 VAC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1150-4GF46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1150-4GF46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.14.6 W
3VA1150-4GF46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1150-4GF46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1150-4GF46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1150-4GF46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1150-4GF46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The interrupting capacity is 121 kA at 240 VAC, stepping down to 75.6 kA at 415 VAC and 52.5 kA at 440 VAC; at 500 V and 690 V it holds 11.9 kA.

The 50 A continuous rating holds across ambient temperatures up to 50 °C without derating; at 55 °C it drops to 49 A, at 60 °C to 48 A, and at 70 °C to 45 A — relevant if the breaker sits in a warm enclosure near other heat sources. The TM240 trip unit is a fixed thermal-magnetic design — no electronic adjustment or communication function — so it is a straight swap for existing thermal-magnetic MCCB installations where selectivity and coordination are already calculated.

Dimensions are 130 mm height, 101.6 mm width, 70 mm depth — fits standard MCCB panel cutouts and DIN-rail adapters for the SENTRON 3VA platform. No undervoltage release, no shunt trip, no ground-fault monitoring module fitted on this variant; those are added via accessory slots if needed.

Frequently asked questions

Where can I buy 3VA1150-4GF46-0AA0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for this MCCB?

The SENTRON 3VA series carries UL, CSA, and IEC certifications; RoHS and REACH declarations are available from Siemens documentation. Specific certificate numbers should be confirmed against the unit's nameplate.

MPN
3VA1150-4GF46-0AA0