Siemens 3VA1150-5ED32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-5ED32-0AA0-ZD00 Circuit Breaker, 55kA @ 415V

MPN3VA1150-5ED32-0AA0-ZD00

Siemens 3VA1 series, IEC frame 160, breaking capacity class M, 3-pole, In=50A, Icu=55kA @ 415V, TM210 line protection, FTFM, Ir=50A fixed, Ii=10 x In, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1150-5ED32-0AA0-ZD00 is a 3-pole IEC frame 160 molded case circuit breaker (MCCB) from the 3VA1 series, configured for line protection with a TM210 thermal-magnetic trip unit. The overload protection is fixed at Ir = 50 A, and the short-circuit pickup is fixed at Ii = 10 × In (500 A). This variant includes a nut keeper kit and is specified for a DC Power OEM application in China.

For a 50 A frame, this is a high-capacity class M rating, suited for main or feeder breakers in industrial switchboards where fault levels are severe. The fixed Ir = 50 A means no adjustment band for overloads; the breaker trips at exactly 50 A continuous, so the downstream load must be sized at or below that. The fixed Ii = 10 × In (500 A) magnetic pickup provides instantaneous trip for short-circuits; it is not adjustable, which simplifies coordination but requires the upstream device to have a higher short-time withstand.

Deployment Context

This MCCB mounts in a standard IEC frame 160 panel cutout or on a DIN rail adapter (not included). The 3-pole design fits three-phase distribution boards, motor control centers, or as a main disconnect in a sub-panel. The nut keeper kit aids captive fastening in OEM assemblies where vibration or repeated access is expected.

Frequently asked questions

How do I get current pricing and availability for 3VA1150-5ED32-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this MCCB?

The Icu is 55 kA at 415 V AC, class M, which is the ultimate short-circuit breaking capacity for a single interruption.

What are the fixed trip settings on this breaker?

Overload protection is fixed at Ir = 50 A; short-circuit protection is fixed at Ii = 10 × In (500 A). No adjustment is available.