Siemens 3VA1150-5EF36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-5EF36-0AB0 SENTRON MCCB, 50 A, 3-Pole, 187 k

MPN3VA1150-5EF36-0AB0

Siemens SENTRON 3VA1150-5EF36-0AB0, molded case circuit breaker, 3-pole, 50 A rated continuous current, TM240 thermal-magnetic release, 187 kA interrupting capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1150-5EF36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1150-5EF36-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1150-5EF36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1150-5EF36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1150-5EF36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1150-5EF36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1150-5EF36-0AB0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The TM240 thermal-magnetic release handles overloads with a thermal delay and instantaneous magnetic trip for short circuits. The 70 mm depth, 76.2 mm width, and 130 mm height fit the standard SENTRON 3VA footprint — it mounts on a DIN rail or panel-mount plate in the same cutout as other 3VA frame sizes. It ships with 2 auxiliary switches (HP type) built in — those are the normally-open/normally-closed contacts that signal the breaker's position to a PLC or status lamp. If you need those functions, you add external modules or look at a different 3VA variant with those options populated.

The 76.2 mm width (3-pole) is the critical dimension for DIN-rail spacing — it takes three 18 mm module positions on a standard DIN rail, same as any other 3-pole MCCB in the 3VA family. The TM240 release is fixed thermal and magnetic; no dials to set, so once it's installed, the protection curve is locked. The 2 auxiliary switches are wired to terminals on the front; they're rated for 240 V AC / 24 V DC control circuits typically.

MPN