Skip to main content
Siemens 3VA1150-5GD42-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA1150-5GD42-0AA0 SENTRON MCCB, 50 A, 4-Pole, 187 kA at 240

MPN3VA1150-5GD42-0AA0
Active

Siemens SENTRON 3VA1150-5GD42-0AA0, molded case circuit breaker, 4-pole, 50 A, TM210 thermal-magnetic trip, 187 kA at 240 VAC, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-5GD42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1150-5GD42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.14.6 W

Protection & Trip Unit

3VA1150-5GD42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1150-5GD42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-5GD42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1150-5GD42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-5GD42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Footprint and panel fit — 70 mm deep, 101.6 mm wide

The 3VA1150-5GD42-0AA0: The breaker occupies 130 mm tall by 101.6 mm wide by 70 mm deep — roughly 4 by 5.12 by 2.76 inches. That 70 mm depth is shallow enough for most 200 mm deep enclosures with gland plate clearance. IP40 on the front means it's protected against tools and wires >1 mm, but not against water ingress — keep it inside a rated enclosure. Four poles in that width means the neutral pole shares the same 50 A rating; no derating needed on the neutral path.

Active lifecycle — BOM-secure for new builds

The lifecycle stage is marked as current — no phase-out or NRND flags. For a panel OEM locking in a BOM, this means the 3VA1150-5GD42-0AA0 is available through normal Siemens distribution channels. No successor part has been announced. If you're replacing an older 5SQ2670-2YA63 or similar frame, check the footprint and trip curve compatibility; the 3VA series uses a different mounting footprint than the older 3VF or 5SQ frames, so a DIN-rail adapter or drill pattern change may be needed.

Frequently asked questions

Does this MCCB have a neutral pole?

Yes, it's a 4-pole breaker — all four poles are rated 50 A. The fourth pole serves as the switched neutral, carrying the same continuous current as the phase poles.

MPN
3VA1150-5GD42-0AA0