Siemens 3VA1150-5MH36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-5MH36-0AA0 SENTRON MCCB, 50 A, 3-Pole, 187 k

MPN3VA1150-5MH36-0AA0
Active

Siemens SENTRON 3VA1150-5MH36-0AA0, molded case circuit breaker, 3-pole, 50 A, TM120M thermal-magnetic release, 187 kA at 240 V, IP40 front, current production.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-5MH36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection

Ratings

3VA1150-5MH36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W

Protection & Trip Unit

3VA1150-5MH36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
Ground-fault monitoringWithout

Construction & Connection

3VA1150-5MH36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-5MH36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1150-5MH36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-5MH36-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB is and where it fits

The Siemens SENTRON 3VA1150-5MH36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 50 A continuous current with a TM120M thermal-magnetic overcurrent release. It carries 187 kA interrupting capacity at 240 V and derates through 121 kA at 415 V, 75.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V — so the same breaker covers low-voltage distribution and motor branch circuits across a wide voltage range without swapping frame sizes. The TM120M release means the thermal element tracks the load current continuously; the magnetic instantaneous pickup is fixed at the TM120M calibration, which suits motor-starting inrush and feeder protection where you need coordination with downstream devices. This is the starter-protection version of the 3VA platform — the product version field confirms it — so it is configured for motor branch-circuit duty rather than straight distribution. The 50 A rating holds flat from 40 °C through 50 °C, then derates to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. In a warm panel (55 °C ambient) you lose only 1 A; at 70 °C you still have 45 A of headroom. The rated insulation voltage is 800 V, so it can be applied in 480/277 V and 600 V systems without a voltage derating concern.

Physical fit and panel integration

Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep. The 70 mm depth clears a standard enclosure with room for wiring and a bus stack behind it. No trip indicator, no undervoltage release, no communication function, no phase failure detection, and no ground-fault monitoring on this variant. If you need a shunt trip, UVR, or electronic trip unit (ETU), this is the wrong order code — those are separate 3VA variants. The TM120M is a pure thermal-magnetic release; no auxiliary power required, no settings to lose on a power cycle.

Lifecycle and sourcing posture

Lifecycle stage is marked current — this is an active, in-production catalog number. No last-time-buy notice, no phase-out date.

Thermal performance and power loss

Maximum power loss is 14.6 W at rated current. Storage temperature range is -40 °C to 80 °C; operating ambient is -25 °C to 70 °C.

Frequently asked questions

Will the 3VA1150-5MH36-0AA0 drop into a panel specified around the 3VA1110-5MH36-0AA0?

Both are 3-pole 50 A TM120M MCCBs in the same 3VA platform — same footprint, same release, same interrupting ratings. The 3VA1150 is the starter-protection version; the 3VA1110 is the standard distribution version. They share the same physical dimensions and mount on the same 3VA panel base, so no rewiring or adapter is needed.

What compliance documentation is available for the 3VA1150-5MH36-0AA0?

The SENTRON 3VA series carries UL, CSA, and IEC certifications standard for molded case circuit breakers. RoHS and REACH declarations are available from Siemens under the 3VA product documentation portal. Specific certificate numbers are not listed in this data set; request them with your RFQ.