Skip to main content
Siemens 3VA1150-6EF32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-6EF32-0AA0 SENTRON MCCB, 50 A, 3-Pole, 220 k

MPN3VA1150-6EF32-0AA0
Active

Siemens SENTRON 3VA1150-6EF32-0AA0, 3-pole molded case circuit breaker, 50 A rated current, TM240 thermal-magnetic release, interrupting capacity 220 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1150-6EF32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1150-6EF32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.14.6 W
3VA1150-6EF32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1150-6EF32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1150-6EF32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1150-6EF32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1150-6EF32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1150-6EF32-0AA0: Interrupting capacity is the headline: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V. At 690 V the 17 kA still covers most motor-drive branch circuits. Three-pole, rated insulation voltage 800 V, front IP40 protection. Max power loss 14.6 W, so ventilation in a sealed enclosure is worth checking if you pack multiple breakers.

Frequently asked questions

What is the interrupting capacity of this MCCB at 240 V?

220 kA at 240 V AC, dropping to 154 kA at 415 V and 121 kA at 440 V.

What overcurrent release does the 3VA1150-6EF32-0AA0 use?

It uses a TM240 thermal-magnetic release — no separate trip unit module required.

What are the mounting dimensions for this breaker?

70 mm deep, 76.2 mm wide, 130 mm tall — standard 3-pole MCCB envelope.

Where can I buy the 3VA1150-6EF32-0AA0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3VA1150-6EF32-0AA0