Siemens SENTRON 3VA1150-6EF36-0JA0 MCCB, 50A, 220 kA at 240V

MPN3VA1150-6EF36-0JA0

Siemens SENTRON 3VA1150-6EF36-0JA0, 3-pole molded case circuit breaker, line protection, 50 A at 40 °C, 220 kA at 240 V, shunt trip release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1150-6EF36-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11506EF360AA0

Ratings

3VA1150-6EF36-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.14.6 W

Protection & Trip Unit

3VA1150-6EF36-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1150-6EF36-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1150-6EF36-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1150-6EF36-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1150-6EF36-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1150-6EF36-0JA0 — 50 A MCCB with Shunt Trip, Line Protection

The Siemens SENTRON 3VA1150-6EF36-0JA0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection in industrial and commercial distribution panels. It carries a continuous rating of 50 A at 40 °C, derating to 45 A at 70 °C — so in a warm enclosure or high-ambient panel, the actual load you can protect may be a few amps lower than the 50 A nameplate suggests. Breaking capacity is the headline here: 220 kA at 240 V, dropping to 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 500 V and 690 V. That 220 kA figure at 240 V means this breaker can safely interrupt a fault current of up to 220,000 A — typical for high-fault utility feeds or transformer secondaries where the available short-circuit current is severe. Rated insulation voltage is 800 V, so the breaker's internal clearance and creepage are sized for 800 V systems, giving headroom on 480 V or 600 V class panels. The shunt trip release (STL) allows remote tripping via a control signal — useful for emergency-stop circuits or supervisory shutdown.

Sourcing & Lifecycle — Active Production, Quoted to Order

The product brand is SENTRON, Siemens' standard line for molded case breakers up to 1600 A. No official successor or alternate MPN is listed in the lifecycle record, so the 3VA1150-6EF36-0JA0 remains the direct order code for this rating and release configuration.

Integration — Panel Fit and Mounting

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures. The 70 mm depth (2.76 in) is shallow enough for compact distribution boards; verify the enclosure depth clearance against the 70 mm plus wiring space. The overcurrent release is a TM240 thermal-magnetic type — fixed thermal and magnetic settings, no electronic adjustment. Trip indicator is not fitted; the breaker relies on the handle position for visual status. Communication function is absent, so this is a standalone breaker, not a smart or networked device.

Frequently asked questions

Where can I buy 3VA1150-6EF36-0JA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to receive a firm price and lead-time estimate.

What is the breaking capacity of 3VA1150-6EF36-0JA0 at different voltages?

220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V.

What is the continuous current rating of 3VA1150-6EF36-0JA0?

50 A at 40 °C, with derating: 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C.

Does 3VA1150-6EF36-0JA0 include a shunt trip?

Yes, it is fitted with a shunt trip (STL) auxiliary release for remote tripping.

MPN