Siemens 3VA1150-6EF36-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-6EF36-0KA0 Circuit Breaker, 50A, 70kA @ 415V

MPN3VA1150-6EF36-0KA0

Siemens 3VA1 IEC frame 160, breaking capacity class H, 3-pole, In=50A, Icu=70kA @ 415V, TM240 overload protection, shunt trip (STL) 220-250V DC / 208-277V AC, clamp connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1150-6EF36-0KA0 is a 3VA1 IEC frame 160 molded case circuit breaker in breaking capacity class H. It's a 3-pole unit rated In=50A with a TM240 thermal-magnetic trip unit providing overload protection adjustable Ir=35A...50A and short-circuit protection Ii=5...10 x In.

The TM240 trip unit is the key selection parameter: overload Ir is adjustable from 35 A to 50 A via a dial on the front, so you set it to the actual continuous load current — not the breaker frame rating. The short-circuit pickup Ii is fixed at 5 to 10 times In (250 A to 500 A at the 50 A setting), which is a fixed magnetic trip, not electronic. That means it's a straightforward thermal-magnetic curve for general distribution or motor branch circuits where coordination with downstream devices is done by time-current curves, not by a digital trip unit. The shunt trip (STL) coil takes 220-250 V DC or 208-277 V AC, so it can be wired to a remote emergency-stop pushbutton or a safety relay without an interposing relay — saves a panel component.

Integration and connections

Clamp (box lug) connections on the line and load side — no tunnel terminals, so you torque down a single screw per phase. Accepts aluminum or copper conductors typical for 50 A feeder circuits. The shunt trip adds a pair of control wires; verify polarity on the DC version if you're wiring it to a 220 V DC control bus.

Frequently asked questions

What is the 3VA1150-6EF36-0KA0 used for?

It's a 3-pole IEC frame 160 molded case circuit breaker rated 50 A, with a TM240 thermal-magnetic trip unit. Used for main feeder or branch circuit protection in industrial panels, motor control centers, and distribution boards where the available fault current is up to 70 kA at 415 V.

Where can I buy the 3VA1150-6EF36-0KA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.