Skip to main content
Siemens 3VA1150-6GD42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1150-6GD42-0AA0 SENTRON MCCB, 50 A, 4-Pole, TM210

MPN3VA1150-6GD42-0AA0
Active

Siemens SENTRON 3VA1150-6GD42-0AA0, molded case circuit breaker, 4-pole, 50 A rated, TM210 thermal-magnetic release, 220 kA at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1150-6GD42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1150-6GD42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.14.6 W
3VA1150-6GD42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1150-6GD42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1150-6GD42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1150-6GD42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1150-6GD42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1150-6GD42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 50 A continuous current at 40 °C, with a TM210 thermal-magnetic release designed for line protection — meaning it handles overloads and short-circuits in distribution panels without communication or ground-fault monitoring built in. The TM210 release gives a fixed thermal pickup and magnetic trip curve suited for cable and busbar protection in commercial and industrial switchboards — not for motor starting duty where adjustable overloads are needed.

The 50 A rating holds flat from 40 °C to 50 °C ambient, then derates to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. Dimensions are 130 mm height, 101.6 mm width, 70 mm depth — a 4-pole MCCB that fits standard Siemens SENTRON mounting bases and busbar systems.

Frequently asked questions

Does 3VA1150-6GD42-0AA0 have a ground-fault or communication function?

No — this MCCB is a line-protection device without ground-fault monitoring, undervoltage release, or communication capability.

MPN
3VA1150-6GD42-0AA0