Skip to main content
Siemens 3VA1163-1AA32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA32-0AF0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA32-0AF0

Siemens SENTRON 3VA1163-1AA32-0AF0, IEC frame 160 3-pole switch disconnector, SD100, rated 63 A continuous, 690 V AC / 500 V DC, IP40 front, with 1 auxiliary switch HQ + 1 trip alarm switch HQ, busbar connection, front terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA32-0AF0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA32-0AF0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1163-1AA32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-1AA32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA32-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Rated 63 A continuous current (Iu) on a 160 A frame, it handles 690 V AC 50/60 Hz and 500 V DC maximum operational voltage. The front terminal busbar connection suits panel builds where the disconnect doubles as a service switch ahead of a motor starter or distribution block. This is a pure disconnect — no overcurrent release, no undervoltage release, no communication module.

Sizing and fit — what the ratings mean

The 63 A continuous rating (Iu) on a 160 A frame means this disconnect is sized for branch circuits up to that load, but the frame itself can handle higher short-time currents. Power loss at 38 W maximum matters for thermal management inside a closed panel — derating adjacent components may be needed if the enclosure is tightly packed.

Mounts in the standard 76.2 mm wide (3-inch) MCCB cutout on a DIN-rail adapter or panel plate — the same footprint as the 3VA1 molded case circuit breakers. Front terminals accept busbar connection for the main circuit; the auxiliary and alarm switch contacts are wired separately via the HQ terminal block. Mechanical endurance is rated at 15 000 operating cycles — suitable for daily switching in a production line, not for high-cycle applications like a welding press that cycles thousands of times per shift. An optional motor drive (product extension) allows remote switching via a PLC output.

Frequently asked questions

What is 3VA1163-1AA32-0AF0 used for?

It is a switch disconnector in MCCB design used for visible isolation and load-break switching of 63 A circuits at up to 690 V AC or 500 V DC, without overload or short-circuit protection. It serves as a service disconnect ahead of motor starters, distribution blocks, or other downstream equipment.

Will 3VA1163-1AA32-0AF0 drop into a panel designed for a 3VA1 molded case circuit breaker?

Yes — it shares the same 76.2 mm width, 70 mm depth, and 130 mm height as the 3VA1 MCCB line, and uses front-terminal busbar connections. The footprint is identical, so no rewiring or cutout modification is needed for a swap.

MPN
3VA1163-1AA32-0AF0