Skip to main content
Siemens 3VA1163-1AA32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA32-0BH0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA32-0BH0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole, SD100, In=63 A, without overload or short-circuit protection, undervoltage release 24 V DC, 2 auxiliary switches HQ + 1 trip alarm switch HQ, busbar connection, front terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA32-0BH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA32-0BH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1163-1AA32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1163-1AA32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA32-0BH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Rated continuous current Iu is 63 A, with a rated insulation voltage Ui of 800 V and a maximum rated operational voltage of 690 V AC (50/60 Hz) or 500 V DC. It carries no overload or short-circuit protection — this is a disconnect-only device, not a circuit breaker, intended for isolation and switching duty where protection is handled upstream or by a separate release.

The 63 A continuous rating (Iu) sets the maximum load current the disconnector can carry without exceeding its thermal limits — sized for a 63 A feeder or motor branch. The 800 V insulation voltage (Ui) and 690 V AC / 500 V DC operational voltage cover standard 400 V three-phase panels and DC bus applications up to 500 V. The 2 kA limited short-time withstand (1 s and 0.5 s) means it can hold off fault current for that duration while an upstream breaker clears; it is not rated for making or breaking fault current on its own. The UVR does not have a leading contact, so it cannot signal an impending trip to a controller before the disconnector opens. The HQ designation means high-quantity switching — rated for frequent operation in control circuits.

The disconnector measures 130 mm high, 76.2 mm wide, and 70 mm deep — a compact footprint for a 63 A MCCB-style device. Main circuit connections are front-terminal busbar connections (nut keeper kit included), which simplifies busbar stacking in a panel. An optional motor drive is available as a field-installable accessory, enabling remote switching via a PLC or building management system.

Frequently asked questions

Does 3VA1163-1AA32-0BH0 include overload or short-circuit protection?

No. This is a switch disconnector only — it provides no overload or short-circuit protection. Protection must be provided upstream or by a separate release (e.g., the undervoltage release fitted here).

MPN
3VA1163-1AA32-0BH0