Skip to main content
Siemens 3VA1163-1AA32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA32-0CA0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA32-0CA0

Siemens SENTRON 3VA1163-1AA32-0CA0, switch disconnector, 3-pole, In=63 A, without overload or short-circuit protection, undervoltage release 120-127 V AC, front busbar connection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA32-0CA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1163-1AA32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W
3VA1163-1AA32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-1AA32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA32-0CA0 is a 3-pole switch disconnector from the SENTRON 3VA series, built in an MCCB-style frame (160 A frame) but configured purely as a disconnect — no overload or short-circuit protection.

Front terminals accept busbar connection; the switch is designed for DIN-rail or direct-panel mounting in a standard MCCB footprint. Dimensions are 70 mm deep, 76.2 mm wide, 130 mm tall — the same width as a 3-pole 160 A frame breaker, so it drops into existing busbar layouts without re-spacing. IP40 on the front face suits enclosed distribution boards; no IP rating on the rear, so it needs a panel or enclosure backplane.

Rated insulation voltage is 800 V, operating voltage 690 V AC / 500 V DC — this switch disconnector is suitable for 400 V and 690 V line-to-line systems. Mechanical service life is 15,000 operating cycles typical; no electrical life figure is listed, but as a no-fault-break switch it is intended for infrequent load-break or isolation duty, not daily motor starting.

Frequently asked questions

How do I get current pricing and availability for 3VA1163-1AA32-0CA0?

Submit an RFQ through this listing; the part is sourced and quoted to order through independent distribution, with availability and current pricing confirmed at quote time.

What is the closest functional second-source for 3VA1163-1AA32-0CA0?

The closest peer in the same 3VA series is the 3VA1110-5EF32-0LA0, but that is a molded case circuit breaker (MCCB) with thermal-magnetic overload and short-circuit protection, not a switch disconnector. The 3VA1163-1AA32-0CA0 has no overcurrent protection — it is a pure disconnect. They share the same frame size, mounting footprint, and terminal arrangement, so the 3VA1163-1AA32-0CA0 can physically replace the MCCB in a panel if overcurrent protection is provided upstream, but the functions are not equivalent.

MPN
3VA1163-1AA32-0CA0