Skip to main content
Siemens 3VA1163-1AA32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA32-0CH0 Switch Disconnector, 63 A, 3-Pole

MPN3VA1163-1AA32-0CH0

Siemens SENTRON 3VA1163-1AA32-0CH0, switch disconnector in MCCB design, 3-pole, 63 A rated continuous current, undervoltage release 120-127V AC 50/60Hz, front busbar connection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA32-0CH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA32-0CH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1163-1AA32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1163-1AA32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA32-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA32-0CH0 is a SENTRON switch disconnector in an MCCB-style housing — IEC frame 160, three poles, rated for 63 A continuous current. It is NOT a circuit breaker; there is no overload or short-circuit release inside. This is a manual disconnect with an undervoltage release (UVR) that drops the load when control voltage falls below the dropout threshold.

Rated continuous current Iu of 63 A means the switch can carry this current continuously without exceeding temperature limits — sized for a 63 A feeder or motor branch circuit where isolation is needed, not protection. The 3-pole design handles three-phase circuits up to 690 V AC 50/60 Hz or 500 V DC. The undervoltage release (UVR) is factory-set for 120-127 V AC control power; if that supply dips, the switch opens automatically — useful for undervoltage protection or emergency-off circuits where a loss of control voltage should disconnect the load. That gives you status feedback for both the switch position and a trip event from the UVR, all in one package without needing a separate auxiliary block.

Dimensions are 70 mm deep, 76.2 mm wide, 130 mm tall — the standard 3VA1 frame 160 footprint. Front terminals accept busbar connection for the main circuit; the auxiliary contacts and UVR terminals are on the front face. The nut keeper kit (included per the description) helps hold busbar connections during installation. Maximum power loss is 38 W — negligible for most panel thermal budgets, but worth checking if you're packing several in a small enclosure.

What it swaps with — and what it doesn't

Physically, the 3VA1163-1AA32-0CH0 shares the same 70 x 76.2 x 130 mm footprint as the 3VA1110-5EE32-0DC0 (a 100 A line-protection MCCB). Both use front terminals and fit the same panel cutout. But functionally they are different animals: the 3VA1110 is a full molded-case circuit breaker with a TM220 thermal-magnetic release; this switch disconnector has no overcurrent protection. If the BOM calls for a disconnect-only device, the 3VA1163 fits. If the panel was designed around the 3VA1110's breaker function, you'd need to add separate fuses or a motor-protective breaker upstream.

Frequently asked questions

Where can I buy 3VA1163-1AA32-0CH0 and how is it quoted?

This part is sourced and quoted to order through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 3VA1163-1AA32-0CH0 drop into a panel specified around 3VA1110-5EE32-0DC0?

Mechanically yes — both share the same 70 x 76.2 x 130 mm frame 160 footprint and front-terminal busbar connection. But electrically no: the 3VA1110 is a circuit breaker with thermal-magnetic protection; this is a switch disconnector only. You must add separate overcurrent protection if the panel design relied on the breaker's trip function.

What is 3VA1163-1AA32-0CH0's rated continuous current?

The rated continuous current Iu is 63 A at 800 V rated insulation voltage, with maximum operational voltage of 690 V AC 50/60 Hz or 500 V DC.

What compliance documentation does this part carry?

The part is designed to DIN EN 81346-2 reference code Q, with IP40 front protection. Standard Siemens SENTRON documentation includes CE marking for the European market; specific UL/CSA or other regional approvals should be verified against the nameplate or the manufacturer's declaration.

MPN
3VA1163-1AA32-0CH0