Siemens 3VA1163-1AA32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA32-0JA0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA32-0JA0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector SD100, 3-pole, 63 A, without overload or short-circuit protection, shunt trip (STL) 110–127 V DC/AC 50/60 Hz, busbar front terminal, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA32-0JA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1163-1AA32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W
3VA1163-1AA32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-1AA32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA32-0JA0 is a SENTRON 3VA1 switch disconnector in MCCB design, rated 63 A continuous current with no derating across the full operating temperature range from 40 °C to 70 °C — meaning it holds its full 63 A rating even in a warm enclosure or high-ambient panel without needing to downsize. It is a 3-pole, non-fused disconnect intended for isolation and switching duty, not for overload or short-circuit protection (no trip unit, no overload release). The built-in shunt trip (STL) release operates on 110–127 V DC or AC 50/60 Hz, allowing remote emergency-off or controlled disconnection from a PLC or safety relay output.

Mechanical endurance is 15,000 operating cycles — typical for a switch disconnector in this frame size. Maximum power loss is 38 W, which matters for enclosure heat load calculations if multiple units are ganged.

Deployment context

Mounts on a DIN rail or panel via the 3VA1 frame footprint (130 mm height, 76.2 mm width, 70 mm depth) and connects via busbar or front terminals — common in Siemens SENTRON distribution boards and MCCB-style switchgear. The shunt trip release makes it a natural fit for safety circuits requiring remote disconnect, such as emergency-stop chains or controlled isolation in automated machinery.

Frequently asked questions

Will 3VA1163-1AA32-0JA0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?

The two parts share the same frame size (3VA1 IEC frame 160) and identical dimensions — 130 mm height, 76.2 mm width, 70 mm depth — so the mechanical footprint is a direct swap. However, the 3VA1010-2ED32-0JA0 is a molded case circuit breaker with overcurrent protection, while the 3VA1163-1AA32-0JA0 is a switch disconnector without overload or short-circuit protection, so the wiring and protection scheme must be reviewed; the busbar connection type also differs (lug terminal on the breaker vs. busbar connection on the disconnect).

MPN
3VA1163-1AA32-0JA0