Siemens 3VA1163-1AA36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA36-0CA0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA36-0CA0

Siemens SENTRON 3VA1, switch disconnector in MCCB design, 3-pole, 63 A rated current flat to 70 °C, 690 V AC / 500 V DC, undervoltage release 120-127 V AC 50/60 Hz, front terminal connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA36-0CA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON

Ratings

3VA1163-1AA36-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W

Construction & Connection

3VA1163-1AA36-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA36-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1163-1AA36-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA36-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch Disconnector with Undervoltage Release — SENTRON 3VA1 Frame 160

The Siemens 3VA1163-1AA36-0CA0 is a 3-pole switch disconnector in the SENTRON 3VA1 family, built in an MCCB-style housing rated for the IEC frame 160. It carries a continuous current rating of 63 A that holds flat across the entire operating temperature range from 40 °C to 70 °C — no derating curve to manage, which simplifies panel thermal budgeting for a 63 A load-break position. Rated operating voltage is 690 V AC and 500 V DC, with an insulation voltage of 800 V. The front-terminal connection accepts lug or clamp terminations for the main circuit, and the unit mounts on a DIN rail in a standard 70 mm depth × 76.2 mm width envelope — a direct fit into existing SENTRON 3VA panel layouts.

Undervoltage Release — UVR 120–127 V AC

This variant ships with an integrated undervoltage release (UVR) rated for 120–127 V AC, 50/60 Hz. The UVR trips the disconnector open when the control voltage drops below the dropout threshold, providing loss-of-voltage protection for downstream loads — a standard requirement for safety isolation in conveyor, pump, and machine-tool circuits where an unexpected restart after a voltage dip must be prevented. No auxiliary contacts are fitted on this order code; the UVR is the only auxiliary release. The UVR does not include a leading contact, so the release operates directly on the undervoltage condition without a time-delay or make-before-break auxiliary. For applications needing a motor-drive option, the product extension for an optional motor drive is available, though it is not included at this order-code level.

Frequently asked questions

What is the difference between 3VA1163-1AA36-0CA0 and the peer 3VA1110-5EF32-0LA0?

The 3VA1110-5EF32-0LA0 is a molded-case circuit breaker (MCCB) with overcurrent protection (TM240 release) and a 100 A rating that derates above 50 °C, while the 3VA1163-1AA36-0CA0 is a switch disconnector with no overcurrent or short-circuit protection, rated at a flat 63 A to 70 °C, and fitted with an undervoltage release instead of a universal release. They share the same 70 mm × 76.2 mm × 130 mm footprint and front-terminal connection, so a panel cutout designed for the MCCB variant will accept the switch disconnector without rewiring, provided the protection scheme is handled upstream.

How do I get current pricing and availability for 3VA1163-1AA36-0CA0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock status are confirmed at quote time and are not published here.

What are the key ratings of 3VA1163-1AA36-0CA0?

Rated continuous current is 63 A flat from 40 °C to 70 °C. Operating voltage is 690 V AC / 500 V DC, with an insulation voltage of 800 V. The undervoltage release is 120–127 V AC, 50/60 Hz. Dimensions are 70 mm depth × 76.2 mm width × 130 mm height.