Siemens 3VA1163-1AA36-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA36-0HH0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA36-0HH0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole SD100, 63 A, without overload or short-circuit protection, shunt trip (STL) 12-30 V DC / 24 V AC, 2 auxiliary switches HQ + 1 trip alarm switch HQ, front terminal connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA36-0HH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1163-1AA36-0HH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W

Construction & Connection

3VA1163-1AA36-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA36-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1163-1AA36-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA36-0HH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens SENTRON order code 3VA1163-1AA36-0HH0 is a 3-pole switch disconnector in the 3VA1 IEC frame 160 series, rated for 63 A continuous current (Iu) without overload or short-circuit protection. It carries a shunt trip release (STL) for 12–30 V DC or 24 V AC 50/60 Hz, plus 2 auxiliary switches HQ and 1 trip alarm switch HQ — a fully kitted control interface for remote trip and status feedback.

Ratings and fit

The 63 A rating is the thermal continuous current (Iu) for unbroken conductor duty — this part is a disconnect switch, not a breaker, so it does not provide overload or short-circuit protection. The 690 V AC maximum operational voltage (Ue) covers 480 V and 600 V class systems; the DC rating goes to 500 V. Short-time withstand is 2 kA for 0.5 s or 1 s, which defines the fault-clearing capability of the switch itself when coordinated with upstream protection. Front terminal connection with clamp terminals for the main circuit. The auxiliary contact block provides 2 CO (changeover) auxiliary switches plus a separate trip alarm contact — three total CO contacts. The shunt trip release is built in, not field-added; no undervoltage release is present. A motor drive can be added as an optional extension. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth. The front face carries IP40 protection; the operating temperature range is -25 °C to +70 °C, with storage from -40 °C to +80 °C. Maximum power loss at rated current is 38 W.

Frequently asked questions

Where can I buy 3VA1163-1AA36-0HH0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between this switch disconnector and the 5SQ2370-2YA05 miniature circuit breaker?

The 5SQ2370-2YA05 is a 0.5 A, 3-pole MCB with C-curve tripping and 3 kA breaking capacity per EN 60898, designed for branch circuit protection on 400 V AC. The 3VA1163-1AA36-0HH0 is a 63 A switch disconnector with no overload or short-circuit protection, for main disconnect duty up to 690 V AC. They are not drop-in substitutes — the 5SQ is a protection device, the 3VA is a disconnecting switch.

What compliance documentation is available for this part?

The SENTRON series carries IEC and UL/CSA certifications for switch disconnector applications. Specific RoHS and REACH declarations are available from Siemens documentation for the 3VA1 platform.

MPN