Siemens SENTRON 3VA1 IEC frame 160 switch disconnector, 3-pole, 63 A, shunt trip (STL) 220-250 V DC / 208-277 V AC, 2 HQ auxiliary switches, front terminal connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA36-0KC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1163-1AA36-0KC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W

Construction & Connection

3VA1163-1AA36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-1AA36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA36-0KC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this part is and what it does

The Siemens 3VA1163-1AA36-0KC0 is a SENTRON 3VA1 IEC frame 160 switch disconnector — a three-pole, 63 A rated device that isolates a circuit under load but provides no overload or short-circuit protection. It is designed as a manual disconnect, not a breaker, so it sits downstream of an upstream protective device. The unit carries a shunt trip release (STL) rated for 220-250 V DC or 208-277 V AC, meaning it can be remotely tripped via a control signal, and it comes with two HQ auxiliary switches for status feedback to a PLC or panel indicator. Rated insulation voltage is 800 V, with a maximum operational voltage of 690 V AC 50/60 Hz and 500 V DC. The part is rated for a short-time withstand current of 2 kA at both 0.5 s and 1 s — this is the fault current it can carry momentarily without damage, not a breaking capacity. It is not a circuit breaker; it is a load-break switch intended for isolation and emergency switching.

Where it fits in the panel

The 3VA1163-1AA36-0KC0 mounts on a DIN rail or panel via the 3VA1 frame base. Dimensions are 70 mm deep, 76.2 mm wide, and 130 mm tall — a compact footprint that matches other 3VA1 frame devices, so it can be swapped into an existing panel layout without re-drilling. Front terminal connections for the main circuit accept lug or clamp-type conductors, and the two auxiliary switches are wired via the front-accessible terminals. IP40 on the front face keeps out tools and fingers; the rest of the enclosure relies on the panel environment.

What the ratings mean for your application

The 63 A rated continuous current (Iu) sets the maximum load this switch can carry continuously without exceeding its thermal limits. For motor loads, size it to the full-load current of the motor plus a margin; for resistive loads, it can run at 63 A continuous. The shunt trip release allows remote tripping from an E-stop or safety PLC — the 220-250 V DC / 208-277 V AC coil voltage means it needs a control supply in that range. The two HQ auxiliary contacts provide a clean signal for status monitoring; they are rated for the same control voltage as the shunt trip. Operating temperature range is -25 °C to +70 °C, with storage from -40 °C to +80 °C. Maximum power loss at rated current is 38 W, which is dissipated through the frame — ensure adequate ventilation in a sealed enclosure. The latching endurance of 15 000 operations is the mechanical life; electrical life will be lower depending on the switched load.

Frequently asked questions

Where can I buy the 3VA1163-1AA36-0KC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between this switch disconnector and the 3VA1110-5EE32-0JA0?

The 3VA1110-5EE32-0JA0 is a molded case circuit breaker with overcurrent protection (TM220 release, 100 A frame), while the 3VA1163-1AA36-0KC0 is a switch disconnector with no overload or short-circuit protection. The 3VA1110-5EE32-0JA0 also has a higher interrupting capacity (187 kA at 240 V) and a different auxiliary contact configuration (no auxiliary switches vs. 2 HQ on the 3VA1163-1AA36-0KC0). They share the same 3VA1 frame dimensions (70 x 76.2 x 130 mm) so they are physically interchangeable in a panel, but they serve different functions — one is a protective device, the other is a dis

Will this part fit in a panel designed for the 3VA1110-5EE32-0JA0?

Yes, both parts share the same 3VA1 frame dimensions (70 x 76.2 x 130 mm) and mounting pattern, so the 3VA1163-1AA36-0KC0 will drop into the same panel cutout and DIN rail position without rewiring the main bus. However, the auxiliary contact wiring may differ — the 3VA1163-1AA36-0KC0 has 2 HQ auxiliary switches, while the 3VA1110-5EE32-0JA0 ships without auxiliary contacts.